Electrical System
84
Service Manual – Advance 7765 / Nilfisk CR1500
Foot Pedal Proximity Switches
The
Foot Pedal Proximity Switches
(sensors)
are mounted adjacent to the bottom
section of the
Foot Pedal
, underneath the
floor of the Operator compartment.
Troubleshooting
Problem
Cause
Correction
No power to the
machine
Discharged battery.
Check the battery voltage and charge as necessary.
Poor battery connection(s).
Check the battery cables, terminals and connections
and tighten/repair/replace as necessary.
Battery needs to be
replaced.
Perform a load test on the battery and replace if
necessary.
Note:
Refer to the individual machine system sections for electrical troubleshooting procedures.
Specifications
Component Specifications
SPDT Relay (R4)
SPST Relay (R1, R2 and
R3)
Operating Current – 140 mA
Nominal Coil Resistance – 85 ± 5 ohms
Foot Pedal
(lower section)
Foot Pedal
Proximity
Switches
Summary of Contents for 56514925
Page 28: ...General Information 28 Service Manual Advance 7765 Nilfisk CR1500 Maintenance Item Locations ...
Page 74: ...Engine System common Electrical System 74 Service Manual Advance 7765 Nilfisk CR1500 ...
Page 89: ...Engine System Diesel 89 Service Manual Advance 7765 Nilfisk CR1500 Starter Relay ...
Page 113: ...Engine System Gasoline LPG 113 Service Manual Advance 7765 Nilfisk CR1500 ...
Page 114: ...Engine System Gasoline LPG 114 Service Manual Advance 7765 Nilfisk CR1500 ...
Page 115: ...Engine System Gasoline LPG 115 Service Manual Advance 7765 Nilfisk CR1500 ...