Solution System 199
Service Manual – Advance 7765 / Nilfisk CR1500
The
Detergent Low Switch
(liquid level
switch) is mounted inside the detergent
tank and switches on the
Low Detergent
light on the instrument panel when the
detergent level is low.
The
Solution High Switch
(liquid level
switch) is mounted in the top of the
solution tank and switches on the
High
Solution
light on the instrument panel
when the solution level is high.
The ESP/
Recycling System On/Off
switch
is mounted on the instrument panel
and controls the power to the ESP and
detergent pumps.
The
Detergent Flow/Off/Max
control knob
regulates the voltage to the detergent
pump to control the pump speed/detergent
output.
Detergent
Low Switch
Solution
High Switch