Sweep System, Main Broom 232
Service Manual – Advance 7765 / Nilfisk CR1500
The
Main Broom Solenoid (2)
valve
is part of the
Main Control Valve
and controls the oil flow to the
main broom motor. The
Main
Control Valve
is mounted on the
underside of the machine, in front
of and to the left of the scrub deck.
When the
Main Broom Solenoid
(2)
valve is energized it closes to
direct the oil flow through
Port 1
on the
Main Control Valve
. The oil is
directed through the main broom
motor and dust control motor,
then returns to
Port 2
on the
Main
Control Valve
.
Main Control Valve
(bottom view - shown mounted in assembled machine)
Main
Control Valve
Port 1
Port 2
Main Control Valve
(top view - shown while machine is being assembled)
Main
Broom
Solenoid (2)