GB
Troubleshooting
21
156
Adria Caravans
21.6
Gas system faults
Tab. 19
Gas system faults
Fault
Possible cause
Measure
Gas smell,
high gas consump-
tion
Gas system leaks.
•
Immediately put the gas sys-
tem out of service.
•
Close the gas cylinder shut-off
valves.
•
Avoid any type of ignition
spark and open light.
•
Ventilate the vehicle well
(Chapter 2.5).
•
Repair by authorised work-
shop.
No gas
Gas cylinder is empty.
•
Exchange gas cylinder
(Chapter 11.5 and 11.6).
Gas cylinder shut-off valve
closed
•
Open gas cylinder shut-off
valve
Gas pressure regulator fro-
zen.
•
Regulator de-icing equipment
(use EisEx).
Quick-action stop valve
closed
•
Open quick-action stop valve
(Chapter 11.6).
Appliance is defective.
•
Repair by authorised work-
shop.
Outside temperature too low.
•
Use propane gas for winter
camping (Chapter 11.3.1).
Flame appearance on
appliance not normal
Gas pressure regulator defec-
tive.
•
Consult an authorised work-
shop.