37
STC2-AL/KL Series
4.4.9
Advanced > Watchdog Timer
4.4.10 Advanced > Super IO Configuration
Passive Cooling Trip Point
Disabled
60 C
70 C
80 C
This value is the temperature
threshold of the Passive Cooling Trip
Point.
Feature
Options
Description
Power-Up Watchdog
Disabled
Enabled
Enables/Disables the Watchdog
Timer
Timeout
0xFFFF
Number of minutes before the power
up watchdog resets the system OS
in hex. Range 0x018-0xFFFF (18-
65535 minutes, 1 min increments)
ATTENTION: Pressing F12 during start up disables the Power Up Watchdog.
RunTime Watchdog
Disabled
Enabled
The RunTime Watchdog resets the
system after a certain amount of time
after power up.
Timeout
0x0018
Time Power Up Watchdog should
wait until it resets the system in hex.
Range 0x018-0xFFFF (18-65535
minutes, 1 min increments)
Feature
Options
Description
Super IO Chip
Info only
► Serial Port 1
Configuration
Sub-Menu
► Serial Port 2
Configuration
Sub-Menu
► Serial Port 3
Configuration
Sub-Menu
► Serial Port 4
Configuration
Sub-Menu
Feature
Options
Description