17
T O R Q U E S E T T I N G S
TORQUE DRIVERS (Recommended):
• UTICA TS-30 (Shown)
ALTERNATIVE DRIVERS:
• Proto J6107A
• Wiha 28887
CAUTION! DO NOT OVER TORQUE SCREWS AS THIS CAN CAUSE LEAKAGE IS-
SUES! TO CONFIRM THE IP65 INTEGRITY AFTER A LAMP REPLACEMENT, TEST
THE FIXTURE USING THE ELATION IP TESTER. CONTACT ADJ SERVICE FOR
MORE DETAILS.
CAUTION! THE USE OF PROTECTIVE GLOVES AND SAFETY GOGGLES IS
STRONGLY RECOMMENDED WHILE PERFORMING THE IP PRESSURE TEST!
AVOID PLACING YOUR FACE, EYES, HANDS, ETC IN CLOSE PROXIMITY TO THE
FIXTURE’S LENS WHILE PERFORMING THE TEST!
IP PRESSURE TESTING PARAMETERS
Low Pressure Limit High Pressure Limit
Steady/Hold Time
2.9 psi
(20 KPa)
3.3 psi
(23 KPa)
15 sec