2/2
A 510
The accessories of the pumps
GB 02992 - Edition 05 - 03/2013
Dimensions
P/N
1 m
A462403-010
3.5 m
A462403-035
5 m
A462403-050
10 m
A462403-100
20 m
A462403-200
Purge valve * (50 sccm)
(driven by the customer
tool)
Air inlet valve *
Air inlet valve cables
and purge valve cables
(for pumps controlled by
Magpower)
The air inlet valve, powered by the
controller, is installed on the pump
exhaust port. It allows to reduce
the braking time of the pump to
put it at the atmospheric pressure.
It is a NC valve which is activated
when the pump nominal speed is
below 10 000 rpm.
Air inlet valve
P/N
24 V DC
114280
Purge valve 50 sccm
P/N
24 V DC
111921S
The gas purge provides an
excellent protection of the maglev
bearings for corrosive applications
and ensures the rotor cooling.
The purge of this valve can be
isolated during an air tightness
test.
* Provide a power line compatible with extra low voltage and safety standards
(SELV).
Dust filter
Dust filter
Water valve
P/N
Water valve
108668
adixen Vacuum Products - Operating Instructions - ATP 2300 M