![Adeunis RF COMFORT MQTT User Manual Download Page 42](http://html1.mh-extra.com/html/adeunis-rf/comfort-mqtt/comfort-mqtt_user-manual_3047350042.webp)
User Guide | COMFORT SERENITY MQTT | NB-IoT / LTE-Cat-M1
42
Parameters
Description
Default Configuration
T3412 Value
Timer defining the period for
periodic Transmission Area
Update (TAU) signal emission
to the network When the
T3412 timer expires, the
product exits a deep sleep
state with no radio activity
(PSM cycle) The value of
T3412 will be multiplied by its
multiplier to obtain the Keep-
alive duration
1
T3412 Multiplier
Multiplier for the T3412 timer
6 hours
T3324 Value
Timer indicating the period
during which the sensor
remains reachable by the
network after a transmission
When the T3324 timer
expires, the product enters
PSM mode but remains
registered on the network
The value of the T3324 timer
will be multiplied by its
multiplier to obtain the Active-
time duration
5
T3324 Multiplier
Multiplier for the T3324 timer
2 seconds
📱
If desired, the user can modify the default cellular network
connection parameters in the product using the NFC IoT
Configurator application:
Go to the "CONFIGURATION" menu of the sensor => Select the
"NETWORK" section => Configure the product => Apply the new
configuration to the product via NFC.