![ADEMCO 7845CZ Installation And Setup Manual Download Page 24](http://html.mh-extra.com/html/ademco/7845cz/7845cz_installation-and-setup-manual_2850308024.webp)
7845CZ Installation and Setup Guide
4–10
Wiring for Radio Faults
You may program the radio fault output (refer to the “Programming” paragraph in this
section) for either:
FAIL-SAFE Mode (UL requirement)
LOW CURRENT Mode
Answer [Y] to “FLT REL ON (Y/N).”
Answer [N] to “FLT REL ON (Y/N).”
Always energized [N.C.].
Normally de-energized [N.O.].
Will change state (and trigger a dialer, if
connected) in the event of power loss.
Does not increase standby current.
Fail-safe mode increases the standby current
by about 10mA, which results in lower
battery backup time (about 15%) in the event
of power loss.
NOT approved for UL installations.
Run two wires from the 7845CZ’s RAD FLT/ECP OUT and GND terminals to a zone on the
control panel. See Figure 8 for wiring the radio fault output.
NOTE: These connections may only be used for panels with common power supply and zone
grounds.
V+
P1 BATT
TB1
7845CZ-009-V0
CONTROL PANEL
7845CZ
BATTERY
ADEMCO
K4362
12V AUX
GND
RAD FLT
GND
ZONE IN
2K EOL
RESISTOR
)LJXUH :LULQJ WKH &= WR 7ULS D &RQWURO 3DQHO =RQH IRU 1RUPDOO\ &ORVHG )DXOW
5HTXLUHG IRU 8/ ,QVWDOODWLRQV
Summary of Contents for 7845CZ
Page 2: ...7845CZZ Installation and Setup Guide ii...
Page 8: ...viii...
Page 38: ...7845CZ Installation and Setup Guide 5 12...
Page 42: ...7845CZ Installation and Setup Guide 6 4...
Page 50: ...7845CZ Installation and Setup Guide 8 4...
Page 56: ...7845CZ Installation and Setup Guide 10 2...
Page 64: ...l K4426CZ 9 01 165 Eileen Way Syosset NY 11791 Copyright 2001 PITTWAY CORPORATION...