3.11 Entering and storing system data
In the next step, you should edit the system data for the axis channel being used in the programm mcfg.
To do this, proceed as follows:
•
The control system must be booted [Online Mode in the header line of the mcfg.exe application]
•
mcfg.exe: [File] [System Data] enter the axis parameters for the respective axes
•
Save the new system data using the [File][Save] command.
•
During the save process, the different parameters are stored residually in the flash memory of the
xPCI-800x controller. If a configuration error was displayed, this must not be displayed again after the
system data has been stored.
•
The save process is finished after a few seconds.