The scope of software is more or less identical to that of the other xPCI-800x boards. However, an
interpolation is only possible with the first 4 axes. The SMLA and SMLR commands can be called up for axes
5 and 6 as well, but only as single-axis traversing commands.
2.3 Limits of use
By using the boards in a PC, the resistance to interference and emission values of the PC may change.
Increased emissions or reduced resistance to interference can mean that the conformity of the system is no
longer ensured.
EMERGENCY STOP functions must not be taken over by any of the above-mentioned modules.
The EMERGENCY functions must be protected separately. This protection must not be influenced by the
boards and the PC.
The board must remain in its anti-static packaging until it is installed.
The warranty claim becomes invalid if the identification numbers are deleted or changed.
2.4 Users
2.4.1 Qualification
The following activities must only be executed by trained electronics employees:
•
Installation
•
Commissioning
•
Operation
•
Maintenance
2.4.2 Personal protection equipment
Please note the national regulations regarding:
•
Accident prevention
•
Installation of electrical and mechanical equipment
•
Electromagnetic compatibility (EMC).
Summary of Contents for APCI-8001
Page 4: ......
Page 47: ...CM COMMISSIONING MANUAL 47 5 4 APCI 8001 component mounting diagram ...
Page 48: ...48 CM COMMISSIONING MANUAL 5 5 APCI 8001 component mounting diagram bottom side ...
Page 49: ...CM COMMISSIONING MANUAL 49 5 6 APCI 8008 component mounting diagram ...
Page 50: ...50 CM COMMISSIONING MANUAL 5 7 APCI 8008 component mounting diagram bottom side ...
Page 51: ...CM COMMISSIONING MANUAL 51 5 8 APCI 8008 STP EVAI component mounting diagram ...
Page 52: ...52 CM COMMISSIONING MANUAL 5 9 APCI 8008 STP EVAI component mounting diagram bottom side ...