LTPH-TP-1044-01, Issue 1
Testing
HXU-358 V1.04
April 6, 2001
49
shows a sample screen for a monitor type external test.
Figure 32.
Monitor Type External Test
To complete an external test head access test, external test
equipment is required. Connect the equipment to the test port
(labeled TEST IN and OUT on the front of the HXU-358).
Additionally, you can connect test equipment to the wirewrap
pins located on the backplane of the Wideband 3190 or ACE.
Main Monitor History Config
Test
Inventory Quit Help
+--------------------+
| T1/E1 Loopback |
| DS3 Loopback |
|
Test Head Access
|
| +----------------------------+
+-| Internal Test Head Access |
|
External Test Head Access
|
+--------------------------------------------------------------+
| Port number: 1 Direction: CUSTOMER Type: MONITOR |
| Test Status: Active on Port 1 |
| Line Format: B8ZS |
| |
| CONNECT DISCONNECT |
+--------------------------------------------------------------+
Test Access on the specified port has been initiated
ID: | Card 'A' 03/30/01 10:59:53 ALARMS: NONE