25
AM.04.510e - Edition 1.5
Maintenance
Connect to PCB
1.
Connect the optical assy to input 1 and 2
on the PCB, if applicable.
Assemble
1.
Install the optical assy (A).
2.
Install the new optical assy screws (D).
See § 7.3.3 (torque).
3.
Lubricate the new gasket of the pressure
release screw.
Use lubricant A.
4.
Install a new gasket on the pressure
release screw (E).
5.
Install the pressure release screw.
See § 7.3.3 (torque).
6.
Install the upper cover assy. See § 5.2.2.
5.2.5
Replace inner cover assy
Parts
-
Inner cover assy
Disassemble
1.
Remove the optical assy. See § 5.2.4.
Assemble
1.
With a new inner cover assy, assemble the optical assy. See § 5.2.4.
-
INPUT 1 and INPUT 2 are
labelled underneath the
connector.
-
When you have an
unidirectional light, connect
the optical assy to
connector INPUT1.
INPUT 2
INPUT 1
Note
Make sure that the locating
pin (B) is set to the hole
marked ‘0’ of the optical assy.
A
E
D
C
B
D