Refer to
Replacing Lens and Flat Gasket
section.
6. Check the electrical insulation from two-pole plug to frame by means of a 500 V insulation tester.
Apply an AC current not exceeding 6.6 A on the two-pole plug and observe normal operation of the LED.
CAUTION
The electronic circuit is designed to be fed from a regulated AC constant current generator only, for example, a
constant current regulator. Do not use a voltage generator as this might damage the electronic components or fail
to energize the light.
Failure to follow this instruction can result in equipment damage.
Note
Refer to
Checking the Light Fixture for Water-tightness
section for instructions on testing.
RELIANCE Omni 1-Dome,
Maintenance
30
Copyright
©
ADB SAFEGATE, All Rights Reserved
Summary of Contents for RELIANCE Omni 1-Dome
Page 1: ...RELIANCE Omni 1 Dome 8 inch User Manual UM 5073 Rev 1 0 2021 07 13 ...
Page 2: ......
Page 8: ...RELIANCE Omni 1 Dome List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Page 10: ...RELIANCE Omni 1 Dome List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Page 20: ...RELIANCE Omni 1 Dome General Information 10 Copyright ADB SAFEGATE All Rights Reserved ...
Page 26: ...RELIANCE Omni 1 Dome Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Page 28: ...RELIANCE Omni 1 Dome Operation 18 Copyright ADB SAFEGATE All Rights Reserved ...
Page 52: ...RELIANCE Omni 1 Dome Maintenance 42 Copyright ADB SAFEGATE All Rights Reserved ...
Page 54: ...RELIANCE Omni 1 Dome Troubleshooting 44 Copyright ADB SAFEGATE All Rights Reserved ...
Page 60: ...RELIANCE Omni 1 Dome POWER TABLE 50 Copyright ADB SAFEGATE All Rights Reserved ...
Page 62: ...RELIANCE Omni 1 Dome CABLE LOSS 52 Copyright ADB SAFEGATE All Rights Reserved ...
Page 66: ......