Also read the following guidelines:
1. Clean the base receptacle. Make sure the base receptacle is completely clean and dry. The mating surfaces must be clean
and free of foreign particles.
2. If, present, fit an appropriate lifting tool into the two threaded holes, which are located 180° apart in the cover.
The lifting tool can be made from two 1/2 x 13 eyebolts (1-inch ID) and a 1/2-inch diameter, 16-inch (406mm) long rod or
pipe inserted through the eyebolts.
Important
Never hold the light fixture by the wires. Doing so may damage the insulation, break the waterproof seal and
cause insulation faults and water leakage.
3. Carry the light assembly to the base.
4. Place the light assembly next to the opening in the L-868 base so that the L-823 connector can be connected with the
mating receptacle from the L-830 or L-831 isolation transformer in the base. Make sure that the connection is solid and
secure. Refer to the Electrical Supply section of the User manual for required isolation transformers.
5. Make sure items such as spacers, shims and gaskets are installed on the light base as indicated on site plans, specifications
and drawings.
6. Position the light assembly over the L-868 base and set it onto the base. Align the light according to FAA AC 150/5345-30
and project plans and specifications. Remove the eyebolts and lifting rod.
Important
Ensure that the cord set wires are NOT pinched between the base can and the fixture. Pinched wires can cause
water to be drawn inside the fixture.
7. If present, lubricate the labyrinth gasket with water. soap may be added to the water (8-inch only).
NOTICE
Do not use silicon or any other type of grease. Avoid the use of soap that contains silicon or glycerin.
8. Attach the six fixing bolts and anti-vibration washers. [See FAA EB-83 (latest revision)]
NOTICE
Due to the risk of bolts vibrating loose, do not use any type of washer with the fixing bolts (such as split lock
washers) other than an anti-vibration washer. Anti-vibration washers as defined in FAA EB-83 (latest revision).
9. Turn on the power to determine whether the LED fixture will illuminate. Operate for a minimum of five minutes.
UM-5073, Rev. 1.0, 2021/07/13
15
Copyright
©
ADB SAFEGATE, All Rights Reserved
Summary of Contents for RELIANCE Omni 1-Dome
Page 1: ...RELIANCE Omni 1 Dome 8 inch User Manual UM 5073 Rev 1 0 2021 07 13 ...
Page 2: ......
Page 8: ...RELIANCE Omni 1 Dome List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Page 10: ...RELIANCE Omni 1 Dome List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Page 20: ...RELIANCE Omni 1 Dome General Information 10 Copyright ADB SAFEGATE All Rights Reserved ...
Page 26: ...RELIANCE Omni 1 Dome Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Page 28: ...RELIANCE Omni 1 Dome Operation 18 Copyright ADB SAFEGATE All Rights Reserved ...
Page 52: ...RELIANCE Omni 1 Dome Maintenance 42 Copyright ADB SAFEGATE All Rights Reserved ...
Page 54: ...RELIANCE Omni 1 Dome Troubleshooting 44 Copyright ADB SAFEGATE All Rights Reserved ...
Page 60: ...RELIANCE Omni 1 Dome POWER TABLE 50 Copyright ADB SAFEGATE All Rights Reserved ...
Page 62: ...RELIANCE Omni 1 Dome CABLE LOSS 52 Copyright ADB SAFEGATE All Rights Reserved ...
Page 66: ......