6.0 Maintenance
This section describes different steps for maintenance of the Omni 1 dome 8-inch light fixture.
6.1 Safety instructions
CAUTION
Electric Shock Hazard
Prior to the commencement of work all electrical services MUST be isolated from the supply and connected to earth.
Full details of the work involved must be given to the authorized Person responsible for the electrical engineering
services at the airport with regard to the duration of the work and so on. It is recommended that prior to starting any
cutting work the nature and location of services such as cable ducts and so on. should be identified Any installation or
maintenance work should only be carried out by trained and experienced personnel.
CAUTION
High Light intensity!
Do not stare directly into the light beam at a close distance.
6.2 Safety Considerations
Read the installation section of all system component manuals before starting these steps. A thorough understanding of
system components and their requirements will promote safe and efficient installation. See FAA AC 150/5340-30, Design and
Installation Details for Airport Visual Aids, and site plans and specifications for field installation of runway and taxiway in-
pavement lights.
DANGER
Failure to follow these safety procedures can result in personal injury or death.
•
Allow only qualified personnel to install ADB SAFEGATE and auxiliary equipment. Use only approved equipment.
Using unapproved equipment in an approved system may void FAA approvals. Observe and follow the safety
instructions in this document and all other related documentation.
•
Make sure all equipment is rated and approved for the environment where it is being used.
•
Follow all instructions for installing components and accessories.
•
Install all electrical connections in compliance with local and national codes and regulations.
•
Use only electrical wire of sufficient gauge and insulation to handle the rated current demand. All wiring must
meet local and national codes.
•
Route electrical wiring along a protected path. Make sure it will not be damaged by moving equipment.
•
Protect components from damage, wear and harsh environmental conditions.
•
Allow ample clearance for maintenance, panel accessibility and cover removal.
•
Protect equipment with safety devices as specified by applicable safety regulations.
•
If safety devices must be removed for installation, reinstall them immediately after the work is completed and
check them for proper functioning.
•
The cord set must be protected prior to installation.
6.3 Maintenance Schedule
Service life depends upon the entire assembly being waterproof. All surfaces must be clean, dry and free of all foreign matter
and all bolts must be properly tightened if the light fixture is to operate for extended periods without requiring maintenance.
UM-5073, Rev. 1.0, 2021/07/13
19
Copyright
©
ADB SAFEGATE, All Rights Reserved
Summary of Contents for RELIANCE Omni 1-Dome
Page 1: ...RELIANCE Omni 1 Dome 8 inch User Manual UM 5073 Rev 1 0 2021 07 13 ...
Page 2: ......
Page 8: ...RELIANCE Omni 1 Dome List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Page 10: ...RELIANCE Omni 1 Dome List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Page 20: ...RELIANCE Omni 1 Dome General Information 10 Copyright ADB SAFEGATE All Rights Reserved ...
Page 26: ...RELIANCE Omni 1 Dome Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Page 28: ...RELIANCE Omni 1 Dome Operation 18 Copyright ADB SAFEGATE All Rights Reserved ...
Page 52: ...RELIANCE Omni 1 Dome Maintenance 42 Copyright ADB SAFEGATE All Rights Reserved ...
Page 54: ...RELIANCE Omni 1 Dome Troubleshooting 44 Copyright ADB SAFEGATE All Rights Reserved ...
Page 60: ...RELIANCE Omni 1 Dome POWER TABLE 50 Copyright ADB SAFEGATE All Rights Reserved ...
Page 62: ...RELIANCE Omni 1 Dome CABLE LOSS 52 Copyright ADB SAFEGATE All Rights Reserved ...
Page 66: ......