6.4.4 Cleaning the Lens
To clean the prism, perform the following procedure:
1. Clean the outer surface of the lens using liquid glass cleaner.
If the prism is coated with a substance impervious to the cleaner, apply a suitable solvent sparingly with a wad of cotton
or a patch of cloth.
2. After the solvent has acted, remove the softened coating with a clean piece of cotton or cloth.
3. Dry the prism with gently, dry, oil-free compressed air at a pressure no greater than 10 psi (0.69 bar) to evaporate or
remove all remaining cleaner.
6.4.5 Testing a LED Assembly
For this test, use a Fluke 87 or equivalent meter.
CAUTION
Do no use the megger function or a resistive test of any meter on an LED assembly! This may damage the LED’s
properties required for proper operation.
A “Diode Test” function may be used as a quick pass/fail check on an LED. In the maintenance shop, open the fixture and
unplug the LED assembly.
1. Set the meter to test a DIODE.
2. Connect the meter leads to the LED assembly.
Observe if the LED glow and also note the meter reading of the LED.
3. Then reverse the meter leads and observe the LED again.
UM-5073, Rev. 1.0, 2021/07/13
25
Copyright
©
ADB SAFEGATE, All Rights Reserved
Summary of Contents for RELIANCE Omni 1-Dome
Page 1: ...RELIANCE Omni 1 Dome 8 inch User Manual UM 5073 Rev 1 0 2021 07 13 ...
Page 2: ......
Page 8: ...RELIANCE Omni 1 Dome List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Page 10: ...RELIANCE Omni 1 Dome List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Page 20: ...RELIANCE Omni 1 Dome General Information 10 Copyright ADB SAFEGATE All Rights Reserved ...
Page 26: ...RELIANCE Omni 1 Dome Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Page 28: ...RELIANCE Omni 1 Dome Operation 18 Copyright ADB SAFEGATE All Rights Reserved ...
Page 52: ...RELIANCE Omni 1 Dome Maintenance 42 Copyright ADB SAFEGATE All Rights Reserved ...
Page 54: ...RELIANCE Omni 1 Dome Troubleshooting 44 Copyright ADB SAFEGATE All Rights Reserved ...
Page 60: ...RELIANCE Omni 1 Dome POWER TABLE 50 Copyright ADB SAFEGATE All Rights Reserved ...
Page 62: ...RELIANCE Omni 1 Dome CABLE LOSS 52 Copyright ADB SAFEGATE All Rights Reserved ...
Page 66: ......