After the test has finished the user can print either the complete test again or
After the test has finished the user can print either the complete test again or
only a summary by pressing the
only a summary by pressing the
[Print/
[Print/
]]
key before returning to normal
key before returning to normal
weighing.
weighing.
The
The complete report
complete report is a
is a copy
copy of the
of the data as
data as shown above.
shown above. If the
If the summary
summary
report is selected then the following is printed. Similar to the above except
report is selected then the following is printed. Similar to the above except
without the interval readings.
without the interval readings.
MOISTURE TEST
MOISTURE TEST
FILE NAME: RES00032
FILE NAME: RES00032
DATE:
13/12/2008
DATE:
13/12/2008
TIME:
09:38:07
TIME:
09:38:07
SER
SER NO:
NO:
XXXXXXXXXXX
XXXXXXXXXXX
USER
USER NO:
NO:
XXXXXXXXXXX
XXXXXXXXXXX
TEST
TEST NO:
NO:
_
_ _
_ _
_ _
_ _
_ _
_ _
_ _
_ _
_
Preset:
Preset:
PST
PST 05
05
Bread-4
Bread-4
Result:
Result:
%
% Moisture
Moisture
Heating:
Step
Heating:
Step
Temp:
Temp:
Step
Step 1
1 120
120 C
C
Time 1 04:00
Time 1 04:00
Step 2 110 C
Step 2 110 C
Time 2 90:00
Time 2 90:00
Rapid
Manual
Rapid
Manual
Interval:
Interval: 30
30 Sec
Sec
Stop:
Time/Stable
Stop:
Time/Stable
60 Min
60 Min
0.002 g
0.002 g
30 Sec
30 Sec
Start:
Manual
Start:
Manual
INIT
INIT MASS:
MASS:
12.341
12.341 g
g
*********** AUTO STOP
*********** AUTO STOP ***********
***********
LAST
LAST TEMP:
TEMP:
111C
111C
TEST
TEST TIME:
TIME:
05:30
05:30 Min
Min
FINAL
FINAL MASS:
MASS:
11.820
11.820 g
g
MASS
MASS LOSS:
LOSS:
0.521
0.521 g
g
RESULT:
RESULT:
4.27
4.27 %M
%M
Heading
Heading
File name used by analyzer to store r
File name used by analyzer to store result
esult
From
From Analyz
Analyzer
er
Add serial number
Add serial number
Add user number
Add user number
Leave a blank line for users to fill in a number if
Leave a blank line for users to fill in a number if
they wish, not from Analyzer memory
they wish, not from Analyzer memory
Settings of the test conditions
Settings of the test conditions
Measured
Measured initial
initial mass.
mass.
TIME STOP if timed out or MAN STOP if user
TIME STOP if timed out or MAN STOP if user
stopped
stopped
Summary of results
Summary of results
Extra LF’s at end of the report
Extra LF’s at end of the report
Summary of Contents for PMB
Page 4: ...P a g e P a g e Adam Equipment Company 2010 Adam Equipment Company 2010...
Page 6: ...P a g e P a g e Adam Equipment Company 2010 Adam Equipment Company 2010...
Page 68: ...P a g e P a g e Adam Equipment Company 2010 Adam Equipment Company 2010...
Page 78: ...P a g e P a g e Adam Equipment Company 2010 Adam Equipment Company 2010...
Page 80: ...P a g e P a g e Adam Equipment Company 2010 Adam Equipment Company 2010...
Page 82: ...P a g e P a g e Adam Equipment Company 2010 Adam Equipment Company 2010...