Multi-Energy Options
A Primary thermal store
B Stainless steel DHW tank
C Heat source from solid
fuel boilers or heat pumps
D Coil heat exchanger
E Immersion heater
F Heat source from solar
panels or heat recovery
from refrigerator
G Heat source from boiler
14
12
Technical Specifications
Note: The above performances are based on a primary flow temperature of 85°C and a domestic cold water inlet of
10°C, without the use of a thermostatic mixing valve on the domestic hot water outlet. If the boiler is heated using
the immersion heater, domestic hot water output depends on the heating element fitted.
Maximum Operating Pressure
Primary:
3 bar
Secondary:
10 bar
Coil:
13 bar
Factory Test Pressure
Primary:
4.5 bar
Secondary:
13 bar
Coil:
20 bar
Maximum Operating Temperature
90°C
HR FB
HR FB
ACCU B
ACCU B
300
450
600
800
Code
06254201
06603202
06240201
06240401
Tank
Total capacity
L
360
450
618
809
Primary capacity
L
189
261
434
625
Heating surface area
m
2
1.99
2.58
2.16
2.16
Primary pressure drop
mbar
90
75
60
60
Primary flow rate
L/h
5400
5700
n/a
n/a
Maximum usable input from boiler
kW
63
63
38
38
Primary connections (female BSP)
Ø
1”
2”
1
1/
4
”
1
1/
4
”
DHW connections (male BSP)
Ø
1”
1
1/
2
”
1”
1”
Immersion heater connection
Ø
1
1/
2
”
1
1/
2
”
1
1/
2
”
1
1/
2
”
Dimensions height
mm
1900
1860
1730
2030
width
mm
680
750
1020
1020
depth
mm
680
750
1020
1020
Weight empty
Kg
190
212
251
280
Weight full
Kg
550
662
869
1089
Coil
Surface area
m
2
2.6
2.6
2.6
2.6
Primary connection (male BSP)
Ø
3/
4
”
3/
4
”
3/
4
”
3/
4
”
Flange diameter
mm
190
190
190
190
Length
mm
610
610
610
610
Pressure drop
mbar
160
160
160
160
Primary flow rate
L/h
700
700
700
700
Rated output
kW
13.12
13.12
13.12
13.12
HR FB
HR FB
ACCU B
ACCU B
300
450
600
800
Peak flow 40°C
L/10’
427
455
280
303
Peak flow 45°C
L/10’
366
390
240
260
Peak flow 60°C
L/10’
220
270
144
182
Peak flow 1st hour 40°C
L/60’
1930
2474
1094
1211
Peak flow 1st hour 45°C
L/60’
1654
2120
938
1034
Peak flow 1st hour 60°C
L/60’
562
726
Continuous flow 40°C
L/h
1804
1940
1089
1089
Continuous flow 45°C
L/h
1546
1662
933
933
Continuous flow 60°C
L/h
653
653
Domestic Hot Water Performances
HR FB/A
C
C
U