User’s Instructions

Powermax HE

85, 115 & 150 Litre
Condensing Boilers with
Integrated Hot Water Storage

MAX0048A

Domestic

Hot Water

'ON' Indicator

Light (Green)

Mains 'ON'

Indicator

Light (Amber)

Burner 'ON'

Indicator

Light (Green)

Lock Out

Indicator

Light (Red)

Lock Out

Reset

Button

Integral Programmer

Controls

Domestic Hot Water

Temperature Control

Boiler ON- OFF

Switch

Central Heating

'ON' Indicator

Light (Green)

Status/Error Code

Display Window

MON

TIME ON 1 ON 2 ON 3

DAY

OFF 3

OFF 2

OFF 1

TUE WED THU FRI SAT SUN

OFF

TIMED

ONCE

ON

OFF
TIMED
ONCE
ON

A

P.M

Programmer

Display

Window

Quick Guide to the Controls

When the Powermax was installed, the Installer should
have - 

left or given you these and other instructions including the
Benchmark Log Book and Potterton Warranty Envelope.

left the programmer showing the current day and time of
day.

Note:

The programmer has default On/Off time

periods for both Hot Water and Central Heating.

About the Control Panel

Status display

Window used to show either operating status e.g. central
heating or hot water, the selected hot water temperature, or
heating system pressure - see chart on Page 7.

Note:

The

display defaults to pressure P (in bar).

Operating errors or fault lock-out conditions are displayed
as E (number) or A (number) - see chart on Page 7.

Note:

Please record the fault code and the boiler Serial No. (see
page 8) when contacting the Service department.

Reset button

Use this button to scroll display when setting the desired
hot water temperature, or checking status or pressure. Use
also to re-start boiler after fault is repaired.

Amber neon

- indicates that the mains electricity 

supply to the boiler is switched on.

Green neon

- indicates that the burner is lit and heating

either the Hot Water or Central Heating.

Red neon

- indicates that the boiler has gone to lock out

and needs to be reset by pressing the Lock-Out reset
button.

Hot water

- the temperature of the stored hot water can

be adjusted over the approximate range of 45 °C to 65
°C.

About the Programmer

The programmer display window will show the current
day, current time of day (12 hour clock) and control status
of both the Hot Water and Central Heating.

If the Central Heating is in a timed OFF period and you
wish to bring it on manually, just press the 'Advance'
button. Similarly if the system is ON and you wish to
switch it OFF, again, press the 'Advance' button.

The programmer settings can be changed to have
different On/Off times for both Hot Water and Central
Heating for each day of the week.

Other Controls

A room thermostat, if fitted, will further control central
heating operation.

Summary of Contents for Powermax HE 85

Page 1: ...r fault lock out conditions are displayed as E number or A number see chart on Page 7 Note Please record the fault code and the boiler Serial No see page 8 when contacting the Service department Reset button Use this button to scroll display when setting the desired hot water temperature or checking status or pressure Use also to re start boiler after fault is repaired Amber neon indicates that th...

Page 2: ... later stage If it is known or suspected that a fault exists on the a ppliance it must not be used until the fault has been corrected by a competent person If a gas leak is suspected turn off the appliance and consult your local gas supplier or service engineer Flammable materials must not be stored in close proximity to the boiler Do not obstruct any purpose provided ventilation openings The mini...

Page 3: ...ler On Off switch to the O OFF position and isolate the gas supply at the boiler It may be advisable to contact your Service Engineer if you wish to do this How your boiler Works Control of the Boiler The boiler is fitted with a control panel which indicates basic functions and also contains a programmer If your installer has fitted another make of programmer remote from the boiler the programmer ...

Page 4: ...ls are allowed to come into contact with the pipe Freezing Conditions If the water temperature within the boiler drops below 5 C a sensor operates and runs the burner to keep the water from freezing This will only operate if the electricity supply to the boiler is ON If you are away during periods of cold weather we recommend leaving your boiler on and adjusting your control system e g thermostat ...

Page 5: ...described in Section 2 0 Page 6 To set up your own ON OFF times refer to Section 3 0 Page 6 If you wish to return to the built in time periods after changes have been made to them firstly ensure the programmer is in Normal Operation Section 1 0 Page 6 Then press hold down the and buttons together after 2 seconds or so release the two buttons and the built in periods will be active Using the HW and...

Page 6: ... Monday If you wish only to change the HW times press the SELECT button under the HW neon and it will start to flash Adjust using or Press STEP and OFF1 will flash Adjust using or 3 3 ON2 OFF2 ON3 OFF3 can be set by repeating the procedure shown for ON1 OFF1 3 4 Once OFF3 has been set press STEP and Tuesday will now flash 3 5 Repeat the procedure for Tuesday and all other days of the week 3 6 Once...

Page 7: ...ff boiler Call Powermax service A 19 Flame detection gas valve fault Switch off boiler Check replace gasvalve press RESET A 20 Flame detected with closed gasvalve Switch boiler off on Press RESET If repeated call Powermax service A 33 Fan speed incorrect Switch boiler off on Press RESET If repeated call Powermax service A 40 System response fault Open radiator valves if shut press RESET If repeate...

Page 8: ...6 000 454 Technical IE Tel 1850 560570 Publication No 5106228 Iss 04 02 2004 BAXI POTTERTON A Trading Division of Baxi Heating UK Ltd Brownedge Road Bamber Bridge Preston Lancashire PR5 6SN Website www potterton co uk company Powermax SEL SEL MAINS ON POWER CH HW PROG PROG C H ADVANC E H W TEMP RESET BURNE R LOCK OUT Cylinder Serial Number label on outside of bottom plinth Heat Engine Serial Numbe...

Reviews: