G
i
»
Wipe the Ascender with a wet cloth
and let it dry. Do not clean the Ascender
with a high-pressure cleaner
»
Clean the Carabiner thoroughly, lubricate
with thin oil and wipe dry
»
Spray the pins with an electronic connector
cleaner/lubricator when needed
Note
DO NOT
use a high-pressure cleaner.
Repairs, annual service and inspection
shall be carried out by an ActSafe-
authorised service partner. More
frequent inspection intervals may be
required because of local regulations.
Cleaning the Ascender
G.01
MAINTENANCE & CLEANING
OF THE ASCENDER
Only use original spare parts and materials
recommended and supplied by ActSafe.
Go through ‘Checklist before use’ (F.11) during every maintenance.
RECOMMENDATION
Basic Inspection Guidance for users and
third party inspection:
To be used safely, each Ascender should meet following
requirements at all times:
» No obvious damage or excessive wear on Ascender
and its components
» Basic function test of Ascender including Emergency
Stop and emergency descent (see section F.10)
» 1,25 x SWL dynamic load test; descending full speed
and then stop with max 10 cm (3,9”) slippage
» 1,5 x SWL static load test; no slippage allowed
60
Summary of Contents for ACX
Page 2: ......
Page 3: ......
Page 15: ...C ROPE Rope type and preparation C 01 15 ...
Page 18: ......
Page 21: ......
Page 25: ...Top Rigged Basic setup Bottom Rigged Basic Setup Double load 25 ...
Page 26: ...Pulley Expert use only Pulley Expert use only ACX pulley rigging on a single anchor 26 ...
Page 42: ......
Page 64: ......
Page 65: ...H POWER ASCENDERS WARRANTY TERMS Warranty terms H 01 65 ...
Page 68: ......
Page 69: ...I TECHNICAL DATA Technical data 1 01 69 ...
Page 71: ...Initial delivery A Inspection B Replaced consumables C Usage log D LOGBOOK 71 ...
Page 77: ...D USAGE LOG Date Signature Comment 77 ...
Page 78: ...D USAGE LOG Date Signature Comment 78 ...
Page 79: ...79 ...