www.acti.com
VMGB-
370 User’s Manual
21
Measure Body Temperature
1. Go
to
Configuration
Temperature Measurement
Body Thermography
Configuration
.
2. Select thermal channel.
3. Click
Draw Area
, then click the mouse on the black body in live view and save it.
4. Set the black body parameters.
Emissivity
: Set the emissivity of black body.
NOTE:
Refer to the emissivity table for reference in the manual or online.
Distance
: The straight-line distance between the black body and the device.
Temperature
: Enter the temperature of the black body.
NOTE:
If there is no black body in the scene, skip step 3 and 4.
5. Set
Environmental Temperature Mode
.
Auto
and
Manual
are selectable. In auto mode,
the device detects environment temperature automatically. In manual mode, you should
enter environment temperature manually.
6. Set the body temperature compensation parameters if you need to detect human body
temperature instead of shell temperature.
i.
Enable body temperature compensation function.
ii.
Select the compensation type.
iii.
In auto mode, the device calculates compensation value automatically. If the
detected body temperature is still inaccuracy, you can set
Manual Calibration
value.
iv.
In manual mode, you should enter
Manual Calibration
value, and corresponding
compensation value displays in
Compensation Value
field.
7. Click
Save
.
8. Set the arming schedule and linkage methods. For the information about arming
schedule settings, see
. For the information about linkage