Slim Multisensor PST02-A/B/C                   

The slim multisensor PST02 has PIR, door/window, temperature and

illumination, 4 sensors function in one, based on Z-Wave

TM

 technology.

It is the  Z-Wave

TM

  plus product, it support the security, OTA... Those

newest  features   of  the  Z-Wave

TM

  technology.  Z-Wave

TM

  is   a  wireless

communication protocol designed for home automation, specifically to

remotely   control   applications   in   residential   and   light   commercial

environments. The technology uses a low-power RF radio embedded or

retrofitted into home electronics devices and systems, such as lighting,

home access control, entertainment systems and household appliances.

This product can be included and operated in any Z-Wave

TM

  network

with other Z-Wave

TM

 certified devices from other manufacturers and/or

other applications.  All non-battery operated nodes within the network

will act as repeaters regardless of vendor to increase reliability of the

network. 

The device adopt the Z-Wave

TM

  500 series chip, when your Z-Wave

TM

network   system   is   all   made   by   Z-Wave

TM

  500   series   devices.   The

network system will have the advantages as below.

Concurrent multi-channel support reduces external interference.

Better RF range, improve about 10 meters in indoor.

Support 100 Kbps transmit speed, speed up communication.

Function Compare A/B/C

PIR

Door/Window

Temperature Illumination

PST02-A

V

V

V

V

PST02-B

V

V

V

PST02-C

V

V

V

Add to/Remove from Z-Wave

TM

 Network

There are two  tamper keys in  the device, one  is in the back  side,

another is in the front side.  Both of them  can add, remove, reset or

association from Z-Wave

TM

 network.

In the first time, add the device into the Z-Wave

TM

 network.  First, make

sure the primary controller is in the add mode. And then power on the 

device, just take out the insulation Mylar in the back side of the device.

The device will auto start the NWI (Network Wide Inclusion) mode. And

it should be included in 5 seconds. You will see the LED light ON one 

second.

Notice

: Including a node ID allocated by Z-Wave

TM

 Controller means 

Add

” or “

Inclusion

”.  Excluding a node ID allocated by Z-Wave

TM

  

Controller means “

Remove

” or “

Exclusion

”.

1

Summary of Contents for PST02-A

Page 1: ...TM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Concurrent multi channel support reduces external i...

Page 2: ...send the Basic Set command to this group And each group support 8 nodes maximum Failed or success in add remove the node ID can be viewed from Z WaveTM Controller Notice 1 Always RESET a Z WaveTM dev...

Page 3: ...led to disable this function by setting the configuration NO 21 to 0 In the default when the temperature is changed to plus or minus one degree Fahrenheit 0 56 degree Celsius the device will report te...

Page 4: ...ion Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low the LED will continue flash about 5...

Page 5: ...unction when installation Normal Mode for the normal operation When the event triggered normally the LED won t indicated unless the battery is in the low level the LED will flash once But in the Test...

Page 6: ...6...

Page 7: ...elease the cover 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push th...

Page 8: ...nafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position...

Page 9: ...tected function And never turn on the light 1 means darkest 99 means brightest 100 means turn off illumination detected function And always turn on the light Notice In none test mode only the value in...

Page 10: ...people in that room 0 Bit4 Disable delay 5 seconds to turn off the light when door window closed 1 Disable 0 Enable 0 Bit5 Disable auto turn off the light after door window opened to turn on the light...

Page 11: ...he interval time for auto report the door window state 0 means turn off auto report NO Name Def Valid A B C Description Time door window state The default value is 12 The tick time can setting by the...

Page 12: ...NSOR_MULTILEVEL_V5 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_ASSOCIATION_GRP_INFO COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_MULTI_CMD COMMAND_CLASS_SECURITY COMMAND_CLASS_...

Page 13: ...ures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver i...