ACRS ELECTRONIC 3 Instruction Manual & Recipes Download Page 35

 
 6 of 23 
 
 

CALENDER 

(OPTIONAL)

 

 
The display shows  

  “CALENDER” 

Continue as it follows:  
 

1. Press 

ENTER

 

 to confirm.  

The display shows  

  “CURRENT DATE FRIDAY  01/01/1999” 

 

2. Press 

ENTER

 

 to set the new date 

The display shows  

  “NEW DATE 01/01/1999” 

 

3. Press 

UP/DOWN

 

 to adjust the day 

 

4. Press 

MENU

  

  

5. Press 

UP/DOWN

 

 to adjust the month 

 

6. Press 

MENU

  

 

7. Press 

UP/DOWN

 

 to adjust the year 

 

8. Press 

MENU

 

  

 

9. Press 

UP/DOWN

 

 to adjust the week day 

 

10. Press 

ENTER

 

. The display shows “Confirm?” Press 

ENTER

 

 to confirm 

the change or 

ESC

 

  to not confirm  

 
11. The display shows again  

  “CURRENT DATE **/**/****”  

(* you will see the date you set)

 

 

12. Press the key 

ESC

 

  to exit   

 
13. The display shows again  

  “CALENDER” 

14. Press the key 

MENU

 

 to pass to the following menu  

Summary of Contents for ELECTRONIC 3

Page 1: ...INSTRUCTION MANUAL FOR DISHWASHING MACHINES MOD ACRS ELECTRONIC 3...

Page 2: ...instruction for the user 2...

Page 3: ...protection 16 Other risks 16 Risk of squeezing the upper limbs 16 Risks of burning the upper limbs 16 INSTRUCTION FOR INSTALLATION AND MAINTENANCE 17 location 18 installation and connections 18 Elect...

Page 4: ...parts or objects with higher dimensions than the working passage of which the machine allows is improper and therefore dangerous 6 The machine must be used only by trained staff 7 The staff handling...

Page 5: ...instruction for the user 5...

Page 6: ...instruction for the user 6 INSTRUCTIONS FOR USE...

Page 7: ...instruction for the user 7...

Page 8: ...those prescribed this applies only to machines with steam heating OPERATION AND USE SWITCHING ON 1 Rotate the main switch Q1 and the switch Q2 to the position I the display shows POWER ON PUSH ON OFF...

Page 9: ...WASHING STOP THE WASHING BY PUSHING STOP DRIVE SYSTEM RUNNING X SPEED STOP THE WASHING 1 Stop the washing by pushing START STOP the display shows MACHINE READY PUSH START TO START THE WASHING DRIVE S...

Page 10: ...ERMOSTAT ACTIVATED TANK EMPTY DRIVE MOTOR HAS JAMMED TERMAL SWITCH ON LOW WATER INLET TEMPERATURE LOW RINSE WATER TEMPERATURE DRYER SAFETY THERMOSTAT ACTIVATED WATER INLET QUANTITY NOT SUFFICIENT DATA...

Page 11: ...nspection doors quickly 3 Use only specific antifoam detergents for industrial dishwashers supplied by well known and reputable companies 4 Disconnect the machine in case of breakdown or defective fun...

Page 12: ...ilters for cleaning 6 Control and if necessary clean the wash and rinse nozzles by removing them from their respective columns Wash the tanks accurately with jets of water 7 For machines with steam co...

Page 13: ...he end of the procedures rinse thoroughly Hygienic care An accurate cleaning of the machine is essential For this operation a special detergent disinfectant is advisable The use of such a product offe...

Page 14: ...l lasts for a very long time it is recommendable to lubricate the stainless steel surfaces with Vaseline oil Self cleaning optional For starting the self wash cycle main switch Q2 has to be put into p...

Page 15: ...everal push buttons near the working places might be necessary Emergency stop push button S3 S3A The discharge side of the machine is provided with a red mushroom shaped push button on yellow backgrou...

Page 16: ...ntion of qualified and authorised staff see paragraph MAINTENANCE Other risks Although the machine is provided with the above mentioned safety devices there are still the risks listed below Risk of sq...

Page 17: ...ON AND MAINTENANCE The following instructions are for qualified staff the only authorised to carry out inspections and repair work if necessary The manufacturer declines all liability for damages due...

Page 18: ...n Remove the panels and position the machine over the connections Place the standard supplied rubber absorbers under the regulation feet of the machine and adjust them to level it if necessary Connect...

Page 19: ...whose efficiency has to be checked according to the valid standard The connection is effected by means of a screw with the identification fitted to the back of the machine The manufacturer declines al...

Page 20: ...it is useful to foresee an interception valve of 1 gas The minimum pressure for this type of supply is 0 5 bar 50kPa 110 8 C and the maximum is 1 5 bar 150 kPa 127 C If especially requested in the ord...

Page 21: ...n OFF Before reactivating it check after having switched on the machine that the boiler is full of water by making sure that water is coming out of the rinsing nozzles Make sure that all motors turn i...

Page 22: ...lowing texts one after the other on the display CONVEYOR SPEED Speed 1 Speed 2 AUTOTIMER connected not connected PREWASH PUMP connected not connected DRYER THERMOREGULATION connected not connected 4 P...

Page 23: ...just succeeds in transporting the total load in second speed up to the extreme end of the exit table after pressing the START STOP button Loading and unloading of the machine For the transport of the...

Page 24: ...te more than 6 of the nominal value c make sure that the absorption of the motors does not exceed the value of the plate d make sure that the motor is regularly supplied with three phases If not so ch...

Page 25: ...achine completely and refill it e check that the air trap is in vertical position Insufficient wash results a make sure that the detergent is efficient and of the type suitable for commercial dishwash...

Page 26: ...ed c check that the fuses and the coils of the contactor relating to the water resistances are not interrupted only for machines with electric heating d check the correct functioning of the heating el...

Page 27: ...very unit Y1 function regularly d the filter of the incoming water is not obstructed e the boiler is not encrusted in such a way as to limit the water flow Insufficient rinse temperature a make sure t...

Page 28: ...make sure that the sluice valve for steam entry is open and that there is steam at a pressure not inferior to 0 5 bar 50 kPa make sure that the filter of the condense discharger is not obstructed mak...

Page 29: ...ACRS E3 2004 eng 04 2005...

Page 30: ...ELECTRONIC 3 TECHNICAL MENU...

Page 31: ...CONFIGURATION LANGUAGE CLOCK new time optional CALENDER current date new date optional TIME SETTING Tprog1 Tprog8 optional TIME ASSOCIATION optional AUTOTIMER RINSE PROLONGATION HYDRAULIC SUPPLY THER...

Page 32: ...Press ENTER The display shows Confirm Press ENTER to confirm the change or ESC to not confirm The display shows again MESSAGES SPEED 4 Press the key MENU to pass to the following menu MACHINE CONFIGUR...

Page 33: ...tor is con nected to the address 5 If not installed the display it shows C SPEED BOARD AD DRESS XXX Pushing the key MENU restarts the indication from the beginning 6 Press ESC to go out of the plannin...

Page 34: ...0 00 3 Press UP DOWN to adjust the hours 4 Press MENU 5 Press UP DOWN to adjust the minutes 6 Press MENU 7 Press UP DOWN to adjust the seconds 8 Press ENTER The display shows Confirm Press ENTER to co...

Page 35: ...ust the day 4 Press MENU 5 Press UP DOWN to adjust the month 6 Press MENU 7 Press UP DOWN to adjust the year 8 Press MENU 9 Press UP DOWN to adjust the week day 10 Press ENTER The display shows Confir...

Page 36: ...rog1 08 00 2 Press MENU to set the new time 3 Press UP DOWN to adjust the hours 4 Press MENU 5 Press UP DOWN to adjust the minutes 6 Press ENTER The display shows Confirm Press ENTER to confirm the ch...

Page 37: ...hows Tprog1 00 00 You have to associate the function ON or OFF with a time previously set Press UP DOWN to associate a time Tprog 6 Press MENU 7 The display shows TIME ASSOCIATION MONDAY Press UP DOWN...

Page 38: ...without autotimer 2 Press MENU The display shows 60 sec This time varies according to the machine model 3 Press UP DOWN to regulate the time 4 Press ENTER The display shows Confirm Press ENTER to conf...

Page 39: ...shows MIN TEMP 30 C This is the minimum for the water inlet temperature If the temperature goes down below this value it appears the alarm LOW WATER INLET TEMPERATURE 2 Press UP DOWN to change the te...

Page 40: ...nes of thermoregulation can be programmed and one without regulation The zones without probe must have shaped as not connected STANDARD CONFIGURATION Sector1 Prewash Sector2 1st wash Sector3 2nd wash...

Page 41: ...e setting The display shows SECTOR 7 1 Press ENTER to confirm The display shows RINSE 2 Press MENU The display shows T setpoint T 80 C 3 Press UP DOWN to regulate the desired temperature 4 Press MENU...

Page 42: ...e previously regulated the drive motor will be not stopped 9 Press UP DOWN to change the data in Stops the drive motor if needed 10 Press ENTER The display shows Confirm Press ENTER to confirm the cha...

Page 43: ...m The display shows again SANITISING SYSTEM 6 Press the key MENU to pass to the following menu ALARM Sounds by starting the washing before moving the belt The display shows ALARM to continue as it fol...

Page 44: ...to continue as it follows 1 Press ENTER to confirm The display shows CONNECTED on machines with 6 speeds motor must be NOT CONNECTED 2 Press UP DOWN to select among CONNECTED or NOT CONNECTED 3 Press...

Page 45: ...ws HPS DATA TRANSMISSION to continue as it follows 1 Press ENTER to confirm The display shows MODE 1 MODE 1 mean Every 10 seconds all the parameters are sent MODE 2 mean Every 10 seconds only the alar...

Page 46: ...display shows FLOWMETER 3 Press MENU The display shows impulse liter 4 Press UP DOWN to regulate a value 5 Press ENTER The display shows Confirm Press ENTER to confirm the change or ESC to not confir...

Page 47: ...ows Confirm Press ENTER to confirm the change or ESC to not confirm The display shows again HPS ENERGY CONSUMPTION 6 Press the key MENU to pass to the following menu HPS CURRENT MEASUREMENT Optional T...

Page 48: ...HPS WATER CONDUCTIVITY OPTIONAL The display shows HPS WATER CONDUCTIBILITY to continue as it follows 1 Press ENTER to confirm The display shows NOT CONNECTED 3 Press MENU The display shows if connecte...

Page 49: ...NTER The display shows CONNECTED 4 Press UP DOWN to select among CONNECTED or NOT CONNECTED 5 Press MENU The display shows for istance T 55 C If the display shows 99 9 C it means that the selected zon...

Page 50: ...ws CONFIRM 2 Press ENTER to confirm Or 3 Press ESC to not confirm CSPEED SETTING optional six speed drive motor The display shows CSPEED SETTING to continue as it follows 1 Press ENTER to confirm The...

Page 51: ...ding delay 10 Press UP DOWN to change the data T 11 Press ENTER Press ENTER The display shows Confirm Press ENTER to confirm the change or ESC to not confirm 12 Press ENTER once again The display show...

Page 52: ...ass to the following menu MAINTENANCE The display shows MAINTENANCE to continue as it follows 1 Press ENTER to confirm The display shows T 10000 Hours 2 Press UP DOWN to increase or decrease the timer...

Reviews: