Summary of Contents for PMC230 Series

Page 1: ...ess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demo...

Page 2: ...0765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 2000 Acromag Inc Printed in the USA Data and specifications are subject to change without notice...

Page 3: ...CABLE SCSI 2 to Flat Ribbon Shielded MODEL 5028 187 14 TERMINATION PANEL MODEL 5025 552 14 DRAWINGS Page 4501 859 PMC MECHANICAL ASSEMBLY 15 4501 863 PMC230 JUMPER LOCATION 16 4501 864 ANALOG OUTPUT C...

Page 4: ...Shielded Model 5028 187 PMC MODULE ActiveX CONTROL SOFTWARE Acromag provides a software product sold separately consisting of PMC module ActiveX Object Linking and Embedding controls for Windows 98 95...

Page 5: ...lts 153 V Full Scale 8000H 10V 0V 5V Notes Table2 1 1 Upon power up or software reset the bipolar ranges will output 0 volts while the unipolar range will output 5 volts Analog Output Range Hardware J...

Page 6: ...ernal trigger input signal or output hardware timer generated triggers to allow synchronization of multiple PMC230 modules As an input the external trigger must be a 5 Volt logic TTL compatible deboun...

Page 7: ...nts of the PCI card The system software accesses the configuration registers to determine how many blocks of memory space the PMC module requires It then programs the PMC module s configuration regist...

Page 8: ...tem reset sets all control register bits to 0 Table 3 3 Control Register BIT FUNCTION 2 1 0 Not Used 1 3 Not Used 1 4 Not Used 1 6 5 External Trigger Control 00 External Trigger Input External and Sof...

Page 9: ...cient on data bits 15 to 8 of the Calibration Coefficient Status register Although the read request via the Calibration Coefficient Access register is accomplished in less then 800n seconds typically...

Page 10: ...ust be programmed for External Trigger Input only mode Data conversion can then be started by writing high to the Start Convert bit of the master PMC230 configured for continuous cycle mode PROGRAMMIN...

Page 11: ...mode of operation which is available on the PMC230 module is used in this example 1 Execute Write of 0100H to Control Register at Base Address 200H a External Software and Internal Hardware timer gene...

Page 12: ...ternal FPGA counters are used to synchronize the simultaneous transfer of serial shift register data to the corresponding converter The DACs can be updated with new digital values or left unchanged Th...

Page 13: ...ents being within specification Field determination of calibration coefficients requires precision test equipment Contact Acromag for technical assistance if field recalibration is needed Surface Moun...

Page 14: ...g Outputs 1 The actual outputs may fall short of the range endpoints due to hardware offset and gain errors The software calibration corrects for these across the output range but cannot extend the ou...

Page 15: ...a flat female ribbon connector at the other end The cable length is 2 meters 6 56 feet This shielded cable is recommended for all I O applications both digital I O and precision analog I O Application...

Page 16: ...RD 16 BIT HIGH DENSITY ANALOG OUTPUT MODULE ___________________________________________________________________________________________ 15 Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 17: ...RD 16 BIT HIGH DENSITY ANALOG OUTPUT MODULE ___________________________________________________________________________________________ 16 Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 18: ...RD 16 BIT HIGH DENSITY ANALOG OUTPUT MODULE ___________________________________________________________________________________________ 17 Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 19: ...RD 16 BIT HIGH DENSITY ANALOG OUTPUT MODULE ___________________________________________________________________________________________ 18 Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 20: ...RD 16 BIT HIGH DENSITY ANALOG OUTPUT MODULE ___________________________________________________________________________________________ 19 Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 21: ...RD 16 BIT HIGH DENSITY ANALOG OUTPUT MODULE ___________________________________________________________________________________________ 20 Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 22: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...