background image

       SERIES PMC230 PCI MEZZANINE CARD                         16-BIT HIGH-DENSITY ANALOG OUTPUT MODULE 

___________________________________________________________________________________________

 

- 5 - 

Table 2.3:  PMC230 Field I/O Pin Connections for P1 

Pin Description 

Number 

Pin Description 

Number 

+CH00 1 

COMMON

1

 26 

-CH00

1

 2 

COMMON

1

 27 

COMMON

1

 3 COMMON

1

 28 

+CH01 4 

COMMON

1

 29 

-CH01

1

 5 

COMMON

1

 30 

COMMON

1

 6 COMMON

1

 31 

+CH02 7 

COMMON

1

 32 

-CH02

1

 8 

COMMON

1

 33 

COMMON

1

 9 COMMON

1

 34 

+CH03 10 

COMMON

1

 35 

-CH03

1

 11 

COMMON

1

 36 

COMMON

1

 12 COMMON

1

 37 

+CH04 13 

COMMON

1

 38 

-CH04

1

 14 

COMMON

1

 39 

COMMON

1

 15 COMMON

1

 40 

+CH05 16 

COMMON

1

 41 

-CH05

1

 17 

COMMON

1

 42 

COMMON

1

 18 COMMON

1

 43 

+CH06 19 

COMMON

1

 44 

-CH06

1

 20 

COMMON

1

 45 

COMMON

1

 21 COMMON

1

 46 

+CH07 22 

COMMON

1

 47 

-CH07

1

 23 

COMMON

1

 48 

COMMON

1

 24 

EXT 

TRIGGER* 

49 

COMMON

1

 25  SHIELD  50 

Notes:

 

1.   The minus leads of all channels are connected to analog 

common on the module. 

 
Analog Outputs: Noise and Grounding Considerations 

 

All output channels are referenced to analog common on the 

module (See Drawing 4501-864 for analog output connections), but 
each channel has a separate return (minus lead) to maintain 
accuracy and reduce noise.  Still, the accuracy of the voltage output 
depends on the amount of current loading (impedance of the load) 
and the length (impedance) of the cabling.  High impedance loads 
(e.g. loads > 100K

Ω

) provide the best accuracy.  For low impedance 

loads, the PMC230 can source up to 5mA, but the effects of source 
and cabling resistance should be considered. 
 

Output common is electrically connected to the PMC module 

analog ground which connects to logic ground of the module at the 
DAC’s.  As such, the PMC230 is non-isolated between the logic and 
field I/O grounds.  Consequently, the field I/O connections are not 
isolated from the carrier/CPU board and backplane.  Care should be 
taken in designing installations without isolation to avoid noise pickup 
and ground loops caused by multiple ground connections.  This is 
particularly important for analog outputs when a high level of 
accuracy/resolution is needed.  Refer to Drawing 4501-864 for 
example output and grounding connections. 

 

External Trigger Input/Output 

 

The external trigger signal on pin 49 of the P1 connector can be 

programmed to accept a TTL compatible external trigger input 
signal, or output hardware timer generated triggers to allow 
synchronization of multiple PMC230 modules. 

 
As an input, the external trigger must be a 5 Volt logic, TTL-

compatible, debounced signal referenced to analog common.  The 
trigger pulse must be low for a minimum of 125n seconds to 

guarantee acquisition.  It must not stay low for more than 6

μ

 

seconds, or additional, unwanted conversions may be triggered.  
The actual conversion is triggered within 6.25

μ

 seconds of the 

falling edge of the external trigger signal.  This type of conversion 
triggering can be used to synchronize generation of analog output 
signals to external events. 

As an output an active-low TTL signal can be driven to additional 

PMC230s, thus providing a means to synchronize the conversions 
of multiple PMC230s.  The additional PMC230s must program their 
external trigger for signal input and convert on external trigger only 
mode.  The trigger pulse generated is low for typically 125n 
seconds.  See section 3.0 for programming details to make use of 
this signal. 

 
PCI Local Bus Connector 

 

The PMC230 module provides a 32-bit PCI interface to the 

carrier/CPU via two 64 pin connectors.  These connectors are 64-
pin female receptacle header (AMP 120527-1 or equivalent) which 
mates to the male connector of the carrier/CPU board (AMP 
120521-1 or equivalent).  This provides excellent connection integrity 
and utilizes gold-plating in the mating area.  Threaded metric screws 
and spacers are supplied with the PMC module to provide additional 
stability for harsh environments (see Drawing 4501-859 for 
assembly details).  The pin assignments of the PCI local bus 
connector are standard for all PMC modules according to the PCI 
Mezzanine Card Specification (see Tables 2.4 and 2.5). 

 

Table 2.4:  PMC Connector Pin Assignments for J1 (32-bit PCI) 

Signal Name 

Pin # 

Signal Name 

Pin # 

TCK 

1 -12V  2 

GND 3 INTA# 4 

INTB# 

INTC# 

BUSMODE1# 7 

+5V 

INTD# 

PCI-RSVD* 

10 

GND 11 

PCI-RSVD* 

12 

CLK 13 GND 14 

GND 15 

GNT# 

16 

REQ# 

17 +5V  18 

V(I/O) 

19 AD[31]  20 

AD[28] 21 AD[27]  22 
AD[25] 23  GND  24 

GND 25 

C/BE[3]# 

26 

AD[22] 27 AD[21]  28 
AD[19] 29  +5V  30 

V(I/O) 

31 AD[17]  32 

FRAME# 33  GND  34 

GND 35 IRDY# 36 

DEVSEL# 37 

+5V 

38 

GND 39 

LOCK# 

40 

SDONE# 

41 

SBO# 

42 

PAR 43 GND 44 

V(I/O) 

45 AD[15]  46 

AD[12] 47 AD[11]  48 
AD[09] 49  +5V  50 

GND 51 

C/BE[0]# 

52 

AD[06] 53 AD[05]  54 
AD[04] 55  GND  56 

V(I/O) 

57 AD[03]  58 

AD[02] 59 AD[01]  60 
AD[00] 61  +5V  62 

GND 63 

REQ64# 

64 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for PMC230 Series

Page 1: ...ess underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demo...

Page 2: ...0765 South Wixom Road P O BOX 437 Wixom MI 48393 7037 U S A Tel 248 624 1541 Fax 248 624 9234 Copyright 2000 Acromag Inc Printed in the USA Data and specifications are subject to change without notice...

Page 3: ...CABLE SCSI 2 to Flat Ribbon Shielded MODEL 5028 187 14 TERMINATION PANEL MODEL 5025 552 14 DRAWINGS Page 4501 859 PMC MECHANICAL ASSEMBLY 15 4501 863 PMC230 JUMPER LOCATION 16 4501 864 ANALOG OUTPUT C...

Page 4: ...Shielded Model 5028 187 PMC MODULE ActiveX CONTROL SOFTWARE Acromag provides a software product sold separately consisting of PMC module ActiveX Object Linking and Embedding controls for Windows 98 95...

Page 5: ...lts 153 V Full Scale 8000H 10V 0V 5V Notes Table2 1 1 Upon power up or software reset the bipolar ranges will output 0 volts while the unipolar range will output 5 volts Analog Output Range Hardware J...

Page 6: ...ernal trigger input signal or output hardware timer generated triggers to allow synchronization of multiple PMC230 modules As an input the external trigger must be a 5 Volt logic TTL compatible deboun...

Page 7: ...nts of the PCI card The system software accesses the configuration registers to determine how many blocks of memory space the PMC module requires It then programs the PMC module s configuration regist...

Page 8: ...tem reset sets all control register bits to 0 Table 3 3 Control Register BIT FUNCTION 2 1 0 Not Used 1 3 Not Used 1 4 Not Used 1 6 5 External Trigger Control 00 External Trigger Input External and Sof...

Page 9: ...cient on data bits 15 to 8 of the Calibration Coefficient Status register Although the read request via the Calibration Coefficient Access register is accomplished in less then 800n seconds typically...

Page 10: ...ust be programmed for External Trigger Input only mode Data conversion can then be started by writing high to the Start Convert bit of the master PMC230 configured for continuous cycle mode PROGRAMMIN...

Page 11: ...mode of operation which is available on the PMC230 module is used in this example 1 Execute Write of 0100H to Control Register at Base Address 200H a External Software and Internal Hardware timer gene...

Page 12: ...ternal FPGA counters are used to synchronize the simultaneous transfer of serial shift register data to the corresponding converter The DACs can be updated with new digital values or left unchanged Th...

Page 13: ...ents being within specification Field determination of calibration coefficients requires precision test equipment Contact Acromag for technical assistance if field recalibration is needed Surface Moun...

Page 14: ...g Outputs 1 The actual outputs may fall short of the range endpoints due to hardware offset and gain errors The software calibration corrects for these across the output range but cannot extend the ou...

Page 15: ...a flat female ribbon connector at the other end The cable length is 2 meters 6 56 feet This shielded cable is recommended for all I O applications both digital I O and precision analog I O Application...

Page 16: ...RD 16 BIT HIGH DENSITY ANALOG OUTPUT MODULE ___________________________________________________________________________________________ 15 Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 17: ...RD 16 BIT HIGH DENSITY ANALOG OUTPUT MODULE ___________________________________________________________________________________________ 16 Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 18: ...RD 16 BIT HIGH DENSITY ANALOG OUTPUT MODULE ___________________________________________________________________________________________ 17 Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 19: ...RD 16 BIT HIGH DENSITY ANALOG OUTPUT MODULE ___________________________________________________________________________________________ 18 Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 20: ...RD 16 BIT HIGH DENSITY ANALOG OUTPUT MODULE ___________________________________________________________________________________________ 19 Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 21: ...RD 16 BIT HIGH DENSITY ANALOG OUTPUT MODULE ___________________________________________________________________________________________ 20 Artisan Technology Group Quality Instrumentation Guaranteed 8...

Page 22: ...uipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentat...

Reviews: