Environmental...
Operating Shock & Vibration Immunity:
Designed to comply with IEC 60068-2-6: 10-
500Hz, 4G, 2 hours/axis, for random vibration, and IEC 60068-2-27: 25G, 11ms half-
sine, 18 shocks at 6 orientations, for mechanical shock.
Installation Category:
Suitable for installation in a Pollution Degree 2 environment
with an Installation Category (Over-voltage Category) II rating per IEC 1010-1 (1990).
Electromagnetic Compatibility (EMC)
Minimum Immunity per BS EN 61000-6-1:
1)
Electrostatic Discharge Immunity (ESD), per IEC 61000-4-2.
2)
Radiated Field Immunity (RFI), per IEC 61000-4-3.
3)
Electrical Fast Transient Immunity (EFT), per IEC 61000-4-4.
4)
Surge Immunity, per IEC 61000-4-5.
5)
Conducted RF Immunity (CRFI), per IEC 61000-4-6.
This is a Class B Product with Emissions per BS EN 61000-6-3:
1)
Enclosure Port, per CISPR 16.
2)
Low Voltage AC Mains Port, per CISPR 14, 16.
Agency Approvals
Electromagnetic Compatibility (EMC
): CE marked, per EMC Directive 2014/30/EU.
FCC Conformity:
This device complies with Part 15, Class B of the FCC rules.
Safety Approvals:
cULus Listed Class I, Division 2, Groups A, B, C, D Hazardous
Location or Nonhazardous Locations only. These devices are open-type devices that
are to be installed in an enclosure suitable for the environment. Consult Factory.
ATEX/IECEx Certified:
ATEX/IECEx Certified for Explosive Atmospheres per ATEX
Directive 2014/34/EU which complies with standards EN IEC 60079-0:2018, EN
IEC 60079-7:2015 +A1:2018, IEC60079-0 Edition 7, and IEC 60079-7 Edition 5.1.
II 3 G Ex ec IIC T5 Gc -40
o
C
≤
Ta
≤
+70
o
C
UL 20 ATEX 2416
X
IECEx UL 20.0088
X
X
= Special Conditions
1)
The equipment shall only be used in an area of not more than pollution
degree 2, as defined in EN/IEC
60664‐1.
2)
The equipment shall be installed in an enclosure that provides a degree of
protection not less that IP 54 and only accessible with the use of a tool in
accordance with EN/IEC
60079‐
0.
3)
Transient protection should be provided and set to a level not exceeding
140% of the peak rated voltage value at the supply terminals to the
equipment.
Reliability Prediction
Reliability Prediction
MTBF (Mean Time Between Failure):
MTBF in hours using MIL-HDBK-217F, FN2.
Per
MIL-HDBK-217, Ground Benign, Controlled, G
B
G
C
Temperature
MTBF (Hours)
MTBF (Years)
Failure Rate (FIT)
25°C
TBD hrs
TBD years
TBD
40°C
TBD hrs
TBD years
TBD