Replacing the Disk Drive
ARX®1000 Hardware Installation Guide
A - 5
For example, the following command shows that the rebuild is 21%
complete. The rebuild progress is shown in bold:
prtlndA1k#
show chassis diskuse
Logical Disk Details:
Disk Status Verification Mode Verification Rate
------ --------------------- ----------------- -----------------
1 Optimal Manual 10 %
Disk Details:
Disk Size State Transfer Rate Model
-------- ----------- ----------------- ------------- -----------------
Bay 1 68.50G Online 320MB/sec ATLAS10K4_73SCA
Bay 2 68.50G
Rebuild 21%
320MB/sec ATLAS10K4_73SCA
RAID Controller Details:
Rebuild Rate Max Transfer Rate Firmware RAID Alarm
------------ ----------------- ------------- ------------
90 % 320MB/sec TL37:G117 Enabled
Disk Usage:
Name Total MB Used MB Free MB Used%
-------------------------------- ---------- ---------- ---------- -----
System 2121 998 1014 50%
Releases 4234 1701 2317 43%
Logs 2121 99 1914 5%
Cores; DiagInfo; Lists 8460 37 7993 1%
Reports; Scripts 46940 66 44489 1%
prtlndA1k#
...
Summary of Contents for ARX 1000
Page 1: ...ARX 1000 Hardware Installation Guide version 4 01 001 810 0006 00 ...
Page 2: ......
Page 5: ...Table of Contents ...
Page 6: ......
Page 9: ......
Page 10: ...Table of Contents x ...
Page 12: ......
Page 22: ......
Page 28: ......
Page 34: ......
Page 42: ......
Page 48: ...Chapter 5 5 8 ...
Page 50: ......
Page 62: ...Chapter 6 6 14 ...
Page 64: ......
Page 70: ......
Page 74: ...Appendix A A 6 ...
Page 75: ...Index ...
Page 76: ......