8
KOOLMASTER PP20-VS2 rev.00
KOOLMASTER PP20-VS2
3.2. Parameter Adjustment
Use the navigation buttons to select the
desired parameter on the main screen. A
parameter that can be modified blinks when
it is selected; non-blinking parameters cannot
be changed.
3.3. Language Selection
The user interface of the controller can be
displayed in multiple languages. Follow these
steps to change the language selection:
Select:
1.
Current Conditions (Main Menu)
More [Otros]
Español [English]
User Settings
Monitoring
Program
Selection
Setup
Time/Date
Español
Use to navigate
The controller automatically changes the
2.
language display.
Press and hold the main menu button
for 5 seconds to switch the language
selection.
3.4. LED Meaning
LED
MEANING
CLEAN MODE
Solid LED:
Clean mode is active.
ALARM
Solid LED:
An alarm condition is active.
A corrective action is required.
Flashing LED:
An alarm condition occurred
but no longer exists.
STIR FAN
Solid LED:
The stir fan output is active.
TUNNEL 2
Open
Solid LED:
Tunnel door #2 is opening.
Close
Solid LED:
Tunnel door #2 is closing.
TUNNEL 1
Open
Solid LED:
Tunnel door #1 is opening.
Close
Solid LED:
Tunnel door #1 is closing.
CURTAIN 2
Open
Solid LED:
Natural ventilation curtain #2 is opening.
Close
Solid LED:
Natural ventilation curtain #2 is closing.
CURTAIN 1
Open
Solid LED:
Natural ventilation curtain #1 is opening.
Close
Solid LED:
Natural ventilation curtain #1 is closing.
INLET 2
Open
Solid LED:
Inlet #2 is opening.
Flashing LED:
The controller opens inlet #2 to reset the
actuator's position.
Close
Solid LED:
Inlet #2 is closing.
Flashing LED:
The controller closes inlet #2 to reset the
actuator's position.
INLET 1
Open
Solid LED:
Inlet #1 is opening.
Flashing LED:
The controller opens inlet #1 to reset the
actuator's position.
Close
Solid LED:
Inlet #1 is closing.
Flashing LED:
The controller closes inlet #1 to reset the
actuator's position.
STAGES 1-12
Solid LED:
Fan stage #x is active.
MINIMUM VENTILATION
Solid LED:
On Time of the minimum ventilation timer.
Flashing LED:
Off Time of the minimum ventilation timer.
HEATERS 1-3
Solid LED:
Heating output #x is active.
MISTING
Solid LED:
On Time of the misting timer.
Flashing LED:
Off Time of the misting timer.
SOAKING
Solid LED:
On Time of the soaking timer.
Flashing LED:
Off Time of the soaking timer.
KOOL-CEL®
Solid LED:
On Time of the Kool-Cel® timer.
Flashing LED:
Off Time of the Kool-Cel® timer.
0-10V 1-2
Solid LED:
0-10V output #x is active.
CLOCK 1-2
Solid LED:
Clock output #x is active.
Summary of Contents for Koolmaster PP20-VS2