4. YUV Alignment Procedure
OSD Default value:
Item
Value
Cal R Offset
127
Cal G Offset
127
Cal B Offset
127
Cal R Gain
127
Cal G Gain
127
Cal B Gain
127
YPbPr R Offset
127
YPbPr B Offset
127
Procedure:
1. Connect power, YpbPr cable (only G cable from DVD player) into projector.
2. Change Timing and play below Color-bar pattern from DVD player.
Timing: 480i
Pattern: Color-bar pattern
(since only G cable is connected, the projected image shows the color bar as black
and white)
3. Light on projector
4. Enter factory mode.
5. Press “Calibration YpbPr” to calibrate the mid level offset.
6. It’s completed.
Color-bar pattern