Accu-Steam™ Gas G2 Installation and Operators Manual
MP5017-1702
PAGE 31
MODE
LED Indicators
DISPLAY
NOTES
Set Preset
Temperature
All indicator LEDs
blinking. Then the
selected preset key
will blink for 3 -5
seconds.
Set Point Value
Use the same process to change the
temperature as detailed in Set Temperature
(On the fly), to adjust the Set Temperature.
Once the correct temperature is displayed,
and before the five second time out, press
and hold the
Preset Temp 1
key or
the
Preset Temp 2
key to save the
displayed value to the desired preset key and
to exit this mode. Press the
On/Off
key
to exit without saving.
Default Values:
Preset 1 =
375°F
Preset 2 =
400°F
Display
Temperature
Mode
Current Temperature
function LED on
Actual temperature
Pressing the
Asterisk
key and the
Up
Arrow
Key will display the current actual
temperature when the unit is in Ready Mode.
User Lockout
Mode
All LEDS on solid
“
Loc
”or “
ULoc
”
To Set USER LOCKOUT mode, press and hold
the
On/Off
key and the
Asterisk
key for approximately four seconds while the
controller is ON. After four seconds, the USER
LOCKOUT parameter will toggle and the dis-
play will show either “
Loc
” or “
ULoc
”. When
buttons are released, the controller will store
the new USER LOCKOUT parameter value into
NVM.
Up Arrow
key (Increment) and the
Down Arrow
key (Decrement) will be
inoperable and the user can’t store new
values into the
Preset
1
or
2
keys.
When
Up Arrow
key or the
Down
Arrow
key (Set temperature on the fly mode)
are held for three seconds the display will
show “
Loc
” when in the “Loc” mode
DIGITAL TEMPERATURE CONTROL QUICK REFERENCE
Summary of Contents for GG24A
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 14: ......
Page 16: ......
Page 29: ...Accu Steam Gas G2 Installation and Operators Manual MP5017 1702 PAGE 22 OPERATION ...
Page 50: ......
Page 54: ......
Page 55: ...Accu Steam Gas G2 Installation and Operators Manual MP5017 1702 PAGE 46 NOTES ...
Page 56: ......