Managers mode is used to setup initial operational parameters for the appliance prior to the first time of production use.
Manager’s mode
1. Entering Managers mode, press and hold the
DOWN arrow key
and the
Asterisk key
for about eight
seconds, to initiate the programming mode for changing controller operating function parameters. In Manager’s
mode, the first field displayed, on the four-digit display, will be the
P# = 1
, DEFAULT COOK TEMP.
2.
The first field displayed, on the four-digit display, will be the P# = 1 Default Cook Temp. (See Fig. 5)
3. To manage the parameters, use
Up Arrow key
and
Down Arrow key
to increment and decrement the
Parameter Number, and use
Preset 2 key
and
Asterisk key
increment and decrement the Parameter Value.
4.
To change the default set temperature display refer to step 3 and set the selected value. ( See Fig.6)
5. When all changes are completed Exit the Managers mode and save the new parameters by pressing the
Preset
2 key
Managers Mode
Mode P# LED1 LED2 LED3 Parameter
Min Setting Max Setting
Default
Display
0
B
B
B
Unit of Measure
0 = F
0 = C
0 (°F)
0/00
1
B
B
B
Default Cook Temperature
200F
90C
400F
205C
350F
175C
350F
175C
2
B
B
B
Ready Mode Display
0
3
0
2/00
Manager
Fig. 5
P#2
Value
Default
Display
Display when there is a ,
or momentary key press
Display when there is a key press
0
rdY
Set Point Temperature
Set Point Temperature
1
Set Point Temperature Set Point Temperature
Actual Temperature
2
rdY
rdY
rdY
3
Set Point
Set Point Temperature
Set Point Temperature
Fig. 6
This chart illustrates the programming logic and program level indication
This chart illustrates details for Parameter 2 Mode Display
Summary of Contents for GG24A
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 14: ......
Page 16: ......
Page 29: ...Accu Steam Gas G2 Installation and Operators Manual MP5017 1702 PAGE 22 OPERATION ...
Page 50: ......
Page 54: ......
Page 55: ...Accu Steam Gas G2 Installation and Operators Manual MP5017 1702 PAGE 46 NOTES ...
Page 56: ......