Accu-Steam™ Gas G2 Installation and Operators Manual
MP5017-1702
PAGE 19
INSTALLATION
TABLE TOP/STAND MODEL - GGF& PGF
TOOLS REQUIRED:
Spirit Level
Manometer
Phillips Screw Driver
Weighted Temperature Probe
Small Blade Straight Screw Driver
Digital Temperature Meter
Digital Volt Meter with ability to read uAmps for
Flame Sense Measurement.
Accutemp Flame Sense Measurement Probes
P/N: ATR-FT003
LOCATION AND PLACEMENT
The ACCU-STEAM™ gas appliance has been
designed to be placed on a commercial kitchen
counter-top, an AccuTemp griddle stand or
directly onto any flat, level surface that will
support the appliance weight.
The operating temperature ranges from 200°-
400°F (93°- 204°C). Since these temperatures
can also be found on surfaces around the
perimeter of this commercial appliance, care
should be given not to install next to or against,
objects or surfaces with a low melting or flash
point.
CLEARANCES
LEVELING
The appliance must be installed in a level
condition. An out-of-level condition may cause
uneven temperatures and in a severe out of level
condition damage to the appliance can occur.
IN-FIELD MODIFICATIONS
This appliance has a totally unique design and is
constructed unlike any other griddle on the market
today. Any modification may permanently damage
the griddle.
CAUTION
This appliance is heavy. For safe handling, the
installer should obtain help as needed or employ
appropriate material handling equipment to remove
the appliance from the skid and move into the final
destination.
WARNING
Only a qualified service or electrician should
complete the installation to ensure that all
electrical and safety requirements are met and
that all wiring is installed as per all current
National, State and Local electrical codes.
WARNING
A
ny in field modifications that bypasses the safety
features could result in injury or death.
WARNING
Always disconnect from power source before
cleaning or servicing.
WARNING
Improper installation, alteration, adjustment,
service, maintenance or cleaning can cause
property damage,injury or death. Read
the installation, operational, maintenance
instructions thoroughly before installing,
servicing or operating this equipment.
WARNING
Installation must conform with local codes , or in the absence of local codes, with the
National Fuel Gas
Code, ANSI Z223.1/NFPA 54, or the Natural Gas and Propane Installation Code, CSA B149.1,
as applicable.
Location
Combustible
Construction
Non-Combustible
Construction
Back
2 Inches
0 inches
Right Side
1 Inch
0 inches
Left Side
1 inch
0 inches
SUITABLE FOR ALL INSTALLATION ON
COMBUSTIBLE FLOORS.
Summary of Contents for GG24A
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 14: ......
Page 16: ......
Page 29: ...Accu Steam Gas G2 Installation and Operators Manual MP5017 1702 PAGE 22 OPERATION ...
Page 50: ......
Page 54: ......
Page 55: ...Accu Steam Gas G2 Installation and Operators Manual MP5017 1702 PAGE 46 NOTES ...
Page 56: ......