6 Utility Functions
6-7
6.12 Marker Counter Reset
This screen is used to check and reset counters for
Markers 1 and 2.
To reset a counter to zero, select it and exit the screen.
6.13 Parameter Mask Utility
This screen is used to hide the selected Device or Basic
Operation parameters from the menu screens. (The
settings for the parameters will remain effective.)
1) Touch the <ON> button followed by “Mask Setting” for
either Device or Basic Operation Parameter. The
corresponding parameter menu is displayed.
2) Touch the parameters you wish to hide on the menu
screens, and they will change color to red.
3) Touch the <Setting End> button on the menu screen
to return to the parameter mask utility screen. The
mask setting is saved onto the hard disk at this point.
4) To restore a hidden parameter, touch the <OFF>
button for the applicable parameter type to display the
menu. Touch a red parameter to change its color back
to black.
5) Touch the <CANCEL> button to display an <ENT> and
a <CANCEL> button. Touch the <ENT> button to
update the mask setting for the Device or Basic
Operation parameters.