The manufacturer guarantees the machine performance if are used pipes and elements that are supplied by it, that can
be find in the table at chapter
TABLE OF
A2B ACCORRONI
PIPES AND ELEMENTS FOR FLUE.
The installer can use other elements but they must be homologated and the pressure losses can’t be superior then the
ones in the table.
When the flue pipe cross a combustible wall or ceiling or is distant less than 25 mm, this pipe must be protected with
another bigger pipe in order that the outside temperature of the protection will be not more than 50°C of ambient
temperature.