DATA SHEET WARM AIR HEATER series
“AS COND" "AS COND EX"
THERMAL PERFORMANCE
Mod.
50
65
80
100
150
175
200
250
300
Rated heat input, Qnom
kW
61,1
76
98,5
122
179
203
238
270
313
Rated heat output, Pn
kW
59,8
73,0
96,3
116,6
178,6
201,8
234,2
269
310
Thermal efficiency at rated heat input, Pn
%
97,9
96,1
97,8
95,6
99,8
99,4
98,4
99,3
98,7
Heat input at 50% of the rated heat input
kW
30,55
38
49,25
61
89,5
101,5
119
162
187,8
Heat rating at 50% of the rated heat
input
kW
31,8
39,0
51,6
62,1
93,8
106,0
123,6
167,3
191,3
Thermal efficiency at 50% of the rated
heat input
%
104,2
102,6
104,9
101,8
104,8
104,5
103,9
103,3
101,8
Minimum heat input Qmin
kW
22
22
31
31
53
53
53
88
102
Heat rating at Qmin
kW
23,3
23,3
33,4
33,4
56,65
56,65
56,65
94,51
109
Thermal efficiency at minimum heat input
Qmin
%
106
106
107,8
107,8
106,9
106,9
106,9
107,4
106,9
Backpressure in the combustion chamber,
with G20 at Qn
mbar
4,3
7,5
3,4
5,1
3,9
5,2
6,2
4
4,8
Backpressure in the combustion chamber,
with G30 at Qn
mbar
4
7,4
3,1
4,7
3,7
5
5,9
3,8
4,6
Condensate produced when the room
temperature is 20°C
l/h
2,15
2,15
4,06
4,06
4,5
4,5
4,5
5,52
5,2
AERAULIC PERFORMANCE
Air flow rate at 18 °C
mc/h
4700
6100
7560
9200
13000
15800
18000
20800
24000
Useful static pressure
Pa
150
150
150
150
200
200
200
200
200
DELTA T AIR at PN °C
°C
37,4
35,1
37,2
37,2
40,4
37,6
38,3
37,1
37
MAX
GAS CONSUMPTION AT 15°C-1013 mbar
METHANE G20 at 20 mbar
mc/h
6,47
8,04
10,42
12,91
18,94
21,48
25,19
28,57
33,12
NAT. GAS G25 at 25 mbar
mc/h
7,52
9,4
12,1
15,0
22,0
25,0
29,3
33,24
38,53
PROPANE G31 at 37 mbar
Kg/h
4,75
5,90
7,65
9,48
13,91
15,77
18,49
20,98
24,32
BUTANE G30 at 28 mbar
Kg/h
4,82
5,99
7,77
9,62
14,12
16,01
18,77
21,29
24,68
CO2 at Qn with G20 (tolerance ± 0.2)
%
8,7
8,9
8,9
8,9
8,8
8,7
8,7
8,3
8,3
CO2 at Qn with G31 (tolerance ± 0.2)
%
10,5
10,5
10,5
10,5
10,5
10,5
10,5
10
10
NOx (≤50 Mg/kWh)
CL
Classe 5
ELECTRICAL DATA
Fan motor capacity
kW x n.
0,736
0,736
1,5
2,2
3
4
5,5
3x2
4 x 2
Fan motor supply voltage
V-Ph-Hz
230 V - 1 - 50
400 V - 3+N - 50
Fan motor absorption
A
7,7
7,7
3,6
5,1
7
9,2
12
7 x 2
9,2 x 2
Fan motor absorption/voltage 3F 230V 50Hz
A
6,2
9,3
12
15
20
12 x 2
15 x 2
Sound pressure (at 5 m)
dB(A)
70
72
72
73
71
73
74
74
75
Protection degree of “XE” “XEO” “XR”
versions
IP
X5D
X5D
X5D
X5D
X5D
X5D
X5D
X5D
X5D
ELECTRICAL DATA, WITH USEFUL PRESSURE = 300 Pa
Fan motor capacity
kW
1,1
1,5
2,2
3
4
5,5
7,5
3 x 2
5,5 x 2
Fan motor supply voltage
V-Ph-Hz
400 V - 3+N - 50
Fan motor absorption/voltage 3F 400V
50Hz
A
2,9
3,6
5,1
7
9,2
12
17,8
7 x 2
9,2 x 2
Fan motor absorption/voltage 3F 230V
50Hz
A
4,8
6,2
9,3
12
15
20
31
12 x 2
15 x 2
Flue connection/combustion air intake
Ǿ
100/100
130/130
150/150
200/200
GAS CATEGORY
is the gas category of the burner
Type of appliance, based on exhaust
devices/combustion air intake
type
B23 – C13 – C33 – C53
Warm air heaters can be used together
with RIELLO burner
RIELLO
RX80
S/PV
RX80
S/PV
RX100
S/PV
RX120
S/PV
RX250
S/PV
RX250
S/PV
RX250
S/PV
RX360
S/PV
RX360
S/PV
Warm air heaters can be used together
with BALTUR burner
BALTUR
BPM
90
BPM
90
BPM
140
BPM
140
BPM
200
BPM
200
BPM
300
BPM
350
BPM
450
Warm air heaters can be used together
with RIELLO burner for GPL - G31
RIELLO
RX250
S/PV
+
pilot
Cod.
20127
965
RX250
S/PV
+
pilot
Cod.
20127
965
RX250
S/PV
+
pilot
Cod.
20127
965
RX360
S/PV
+
pilot
Cod.
20127
965
RX360
S/PV
+
pilot
Cod.
20127
965