22
AJBOX1 FEED CABLE PREP
The AJBOX1 is quite compact considering the number of connections required within it. For
best results we recommend that you prepare all cables in the manner shown here in order
to provide just enough flexibility without filling the box with excess cable.
The DMX hot and cold out connections (red/white and white/black striped) are not used
and can be trimmed. We suggest that you cut them short at slightly different lengths and
ensure that no conductors are visible. Optionally, you could also cap them off. Double check
that they cannot short together and are well away from the mains connections.
1"
2"
3"
2.76" 3.15"
0
10
20
30
40
50
60
70
80
0
CABLE TRIM RULER
When this document is printed at 100%, the gauge below is accurate to scale.
IMPORTANT: Ensure that
the AC
Earth
and DMX
Ground
are tied to a true
earth before entering the
AJBOX1.