11: CFM
9. Open the CFM > LBM and click on the MEPID, then click Start to start the link trace.
•
MEP index: Unique index assigned to each Maintenance association End Point.
•
MEPID: Maintenance association End Point Identifier.
•
Target type: Allows setting the loopback target by remote MEPID or MAC address.
•
Remote MEPID: Specifies the target remote MEPID. The remote MEP MAC address should be resolved into the
local MEP database.
•
MAC address: Specifies the target MAC address. Only unicast MAC address are valid for loopback target
address.
•
VLAN priority: Specifies how to determine the LBM VLAN priority value:
o
CCM priority : Use the same priority that MEP CCMs.
o
Specific : Use a specific value specified by the Priority field.
•
Priority: Specifies the value for LBM VLAN priority.
•
VLAN drop eligibility: Specifies the value for LBM VLAN drop eligibility bit.
•
Nbr message: Specifies the number of LBM to send.
•
Interval: Specifies the interval between LBM in milliseconds. Valid values are between 100 and 5000 inclusively.
•
Data TLV: Indicates if LBMs should include a Data TLV.
o
None : No Data TLV included.
o
Incremental : A Data TLV with incremental byte values will be included.
o
Pattern : A Data TLV based on a user data pattern will be included.
•
Length: Specifies the amount of data bytes inside the data TLV. Valid values are between 1 and 1488 inclusively.
•
Pattern: Specifies a user data pattern for the Data TLV.
•
Loopback request: Indicates if a loopback request is active for that MEP.
•
Target MAC address: Indicates the target MAC address used by the latest loopback request.
Summary of Contents for EtherNID EE
Page 8: ...8 Alarms 199 1 APPENDIX B MIB SUPPORT 203 Public MIBs 203 Private MIBs 205...
Page 71: ...4 Port configuration...
Page 121: ...6 Alarms Alarm configuration The Alarm Configuration page lists all defined alarms...
Page 164: ...9 Performance Assurance Agent 3 Configure parameters and click Apply...
Page 191: ...11 CFM 10 Open the CFM DMM Configuration and select add...