11: CFM
11 CFM
C
CFM continuity fault management
To view a list of all CFM instances and their settings, open the CFM > Stack tab.
CFM stack:
•
Stack: Central location to view all the CFM information.
•
Port: This object represents the Bridge Port or aggregated port on which MEPs might be configured.
•
VID: VLAN ID to which the Maintenance Point is attached, or 0, if none.
•
Level: MD level (or MEG level) of the Maintenance Point.
•
Dir: Direction in which the Maintenance Point faces on the port.
•
MID idx: The index of the Maintenance Domain to which the MP is associated, or 0 for MEGs.
•
MA idx: The index of the Maintenance Domain to which the MP is associated, or 0 for MEGs.
•
MEPID: The MEPID of the MEP.
•
MAC address: MAC address of the Maintenance Point.