![background image](http://html.mh-extra.com/html/ac/stag-400/stag-400_installation-manual_454619043.webp)
AC S.A. All rights reserved. Copying, publishing, distribution and any usage of the full or partial data included in the herewith document, particularly pictures, drawings, illustrations, trade marks etc. is
strictly prohibited under the law.
Page 43 of 54
2.1.12
Gas level indicator
Click the right mouse button on the switchboard in order to edit settings of the Gas level
indicator. A setting window will be displayed, which enables selection of threshold voltage values
for the indicator.
Figure 2.1.32
“Gas level indicator” window
The window enables access to the following settings:
•
Gas level sensor type –
the user can select from among the following LPG level sensors:
WPGH Hall sensor (3-wire), 50 [kOhm], 90 [Ohm] resistance sensors (2-wire)
•
Characteristics –
sensor signal increment method: decreasing or increasing
•
Sound level –
buzzer volume, 4 levels
•
LED brightness level
– LED brightness setting for the level indication
•
Buzzer position
– once LED400 has been installed, the user must select the location of the
speaker, to ensure correct visualisation of the LPG level indication.
•
Auto brightness
adjust.
The voltage boxes can be edited in order to ensure correct level indication. Once the sensor type
has been selected, set the extreme values for en empty and a full tank, by setting the voltage
values, including a margin, to ensure correct indication for the “Empty” and “Full” reading. Enter
intermediate values, in appropriate proportions, in both of the middle boxes.