Select the controller (e.g. STAG 400 DPI model A1) or LED switchboard (LED-400) in
Devices
parameters
window, to proceed with the firmware update. Connect the logger and use
Find
Recorder
button in order to update the firmware of the Stag Parameter Logger. Subsequently,
select the desired firmware version from
Available updates
window. In the event the list of
available updates is not displayed, click on
Read Update
button and select the desired file from
the computer's hard drive. Having selected the desired firmware version, click on
Update
button.
Wait until the update process has been completed. The update process progress is reflected by
the progress bar. The engine must be turned off during the update.
Figure 2.1.36
“Devices update” window
2.2
Programming the controller
2.2.1
Auto-calibration
Auto-calibration is possible once the reducer temperature has reached the level of 60 °C. Start
the engine and wait until the lambda probe starts working before proceeding with the auto-
calibration procedure. Appropriate LTFT and STFT corrections are important when running on
petrol. Usually correction values should oscillate around 0%. When performing auto-calibration,
the engine should work at idle run. Do not rev up the engine, AC and the lights should be turned
off. Do not move the steering wheel, as this might result in an incorrect course of the calibration
procedure. Once
Auto-calibration
window has been selected and
Start
button clicked, the
Choose engine code
window will be displayed.