Network
50
Setting the HOST / OTHERS
Leg en Si e i
Parameter
Setting
Alarm Host IP
No function
Alarm Host Port
No function
Server Port
Port for data communication
HTTP Port
Port for web server
Multicast IP
In order to minimize traffic you can
enter a Multicast IP. The IP address
has to match the IP address of the
PC running the CMS software.
MTU
Describes the max. size of the largest
protocol data .
Note
Server port 8000 and HTTP port 80 are the stan-
dard ports for remote clients and remote Internet
browser access.
Setting up an e-mail address
In the event of an alarm, the device can send a message
by e-mail. Enter the e-mail configuration here:
Leg en Si e i
Parameter
Setting
Server Au-
thentication
Tick the box when authentication is
made on the server of the Internet pro-
vider
User Name
E-mail account at the provider
Password
Password connected to the e-mail ac-
count
SMTP Server
SMTP server address of the provider
From Name
Name of the sender
From Email
Address
Corresponding e-mail address for the
e-mail account
Select Recipi-
ents
Select three possible recipients for the
e-mail
To Name
Enter the name of the recipient here
To Email Ad-
dress
Enter the e-mail address of the
recipient here
“Advanced”
tab
Setting
Attached
JPEG File
Tick the box when camera images
should also be sent with the e-mail as
photo files
Interval
Select the interval between the
individual recordings (2 to 5 seconds)
SMTP Port
Enter the SMTP port here
(Default: 80)
SSL
Tick the box to activate the e-mail
encryption