Page 1: ...6LHPHQV Digital Video Recorder SISTORE AX8 1000 200 V4 0 SISTORE AX16 1000 400 V4 0 Installation Manual ...

Page 2: ...peration Manual NOTE This document cannot deal with every possible application Further useful product information as well as application examples and supplementary information to the manuals can be found on our intranet website https psp sbt siemens com Product Support Platform Trademarks SISTORE is a trademark of Siemens Microsoft is a registered trademark and Windows a trademark of Microsoft Cor...

Page 3: ...monitor 11 6 4 Connecting a VGA monitor 11 6 5 Connecting Audio In Out 12 6 6 Connecting alarms 12 6 7 Connecting to the RS485 port 13 6 8 Connecting to the USB ports 14 6 9 Connecting to the RS232 port 14 6 10 Connecting to the network port 14 6 11 Factory reset 15 6 12 Connecting the power cord 15 6 13 Connector pin outs 16 6 14 Connection diagrams 17 6 14 1 Connecting the remote keyboard CKA482...

Page 4: ......

Page 5: ...n installation operation or disposal of a product must be adhered to in addition to the instructions in the product documentation Radio interference with other devices in the environment z This is a Class A device This equipment may cause radio interference in a residential installation In this case the user is encouraged to perform appropriate measures to correct the interference z The device may...

Page 6: ... objects on the device Danger of electrical shock due to incorrect connection z Use the device only in conjunction with a power supply cable that has been approved in your country and complies with the national standards z This product is designed for TN power systems and for IT power systems in Norway with 230 V phase to phase voltage Do not connect the device to any other IT power systems Damage...

Page 7: ...quirements of the following European directives The EU declaration of conformity is available to the responsible agencies at Siemens AG Siemensallee 84 76181 Karlsruhe Germany European Directive 2004 108 EC Electromagnetic Compatibility Compliance with the European Directive 2004 108 EC has been proven by testing according to the following standards Emitted interference EN 61000 6 4 EN 55022 Class...

Page 8: ...remote keyboard User administration 64 groups 256 users groups access right programmable per group Recording Playback Compression H 264 technology video ADPCM audio Recording speed SISTORE AX8 up to 200 ips PAL up to 240 ips NTSC SISTORE AX16 up to 400 ips PAL up to 480 ips NTSC Recording resolution CIF 2CIF 4CIF Recording mode Time Lapse Event Pre Event up to 30 min Text In Panic Search mode Date...

Page 9: ...hen installing an internal DVD RW drive connect the SATA I O cable to the SATA3 socket 4 Details for ordering Type Order No Designation Weight SISTORE AX8 1000 200 S54569 C72 B3 SISTORE AX8 1000 GB 200 ips 10 2 kg SISTORE AX16 1000 400 S54569 C92 B3 SISTORE AX16 1000 GB 400 ips 10 2 kg 5 Scope of delivery z Digital video recorder z Power cord z CD ROM including Configuration Operation Manual Multi...

Page 10: ...power supply before installing the device The diagram below shows a typical DVR installation Fig 1 Typical DVR installation Fig 2 16 channel DVR rear panel 1 Video Input 6 RS232C Port 2 Video Loop Through 7 Audio In Out 3 RS485 Port 8 Video Out 4 Alarm Input Output 9 Factory Reset Switch 5 Network Port 10 Power Cord Connector ...

Page 11: ...cting the loop through video Fig 4 Video loop through connectors If you would like to connect your video source to another device you can use the Loop BNC connectors NOTE The Loop BNC connectors are auto terminated Do not connect a cable to the Loop BNC unless it is connected to a terminated device because it will cause poor quality video 6 3 Connecting the monitor Fig 5 Video Out connectors Conne...

Page 12: ...mplifier The DVR does not have a pre amplifier for audio input so the audio input should be from an amplified source not directly from a microphone 6 6 Connecting alarms Fig 8 Alarm Input connectors NOTE To make connections on the Alarm Connector Strip press and hold the button and insert the wire in the hole below the button After releasing the button tug gently on the wire to make certain it is ...

Page 13: ...s internal buzzer Mechanical or electrical switches can be wired to the ARI Alarm Reset In and GND Ground connectors The threshold voltage is below 0 3V and should be stable at least 0 5 seconds to be detected Connect the wires to the ARI Alarm Reset In and GND Ground connectors 6 7 Connecting to the RS485 port Fig 11 RS485 connector The DVR can be controlled remotely by an external device or cont...

Page 14: ...a computer A USB to Serial converter can be connected to the USB port Multiple text in devices can be used with a USB to Serial converter 6 9 Connecting to the RS232 port Fig 13 RS232 connector An RS232 port is provided to connect a remote control keyboard 6 10 Connecting to the network port Fig 14 Network connector The DVR can be networked using the 10 100Mb Ethernet connector Connect a Cat5 cabl...

Page 15: ...EDs on the front panel are lit NOTE When the DVR successfully resets to factory defaults all the LEDs on the front panel flash five times 5 Release the reset switch Î All of the DVR s settings are now at the original settings it had when it left the factory 6 12 Connecting the power cord Fig 16 Power cord connector Connect the AC power cord to the DVR and then to a wall outlet CAUTION Route power ...

Page 16: ...arm Outputs Normally Open C Relay Common ARI Alarm Reset In RS485 connector pin outs Master unit Slave unit RX TX J To J TX RX RX TX J To J TX RX RS232 connector pin outs Pin 1 DCD Data Carrier Detect Pin 2 RXD Receive Data Pin 3 TXD Transmit Data Pin 4 DTR Data Terminal Ready Pin 5 GND System Ground Pin 6 DSR Data Set Ready Pin 7 RTS Request To Send Pin 8 CTS Clear To Send Pin 9 RI Ring Indicator...

Page 17: ... n In the menu RS232 RS485 RS232 RS485 Baud Rate 19 200 19 200 CCDA1415 1200 9600 CCDA1425 1435 Parity None None Data Bit 8 8 Stop Bit 1 1 Usage Remote control PTZ control Pin out RS232 connection SISTORE AX RS 232 CKA4820 RS232 Com 1A Pin 1 Pin 1 Pin 2 Pin 3 Pin 3 Pin 2 Pin 5 Pin 5 Pin 9 Pin 9 Pin out RS485 connection SISTORE AX RS 485 CCDA14xx Tx Data Tx Data RS485 SISTORE AX ID 1 RS232 CKA4820 ...

Page 18: ... View Stored fixed camera position that you can return to by entering the preset number Auto panning The dome camera will perform an auto scan operation Tour Repeat pre configured sequence of presets that the dome will move between continuously Device menu Open the menu of the dome for configuration OSD navigation Once the OSD is displayed on the video output navigation and parameter setup can be ...

Page 19: ...Alarm In Alarm Device Mechanical alarm input device can be used as above and 5 V TTL logic can also be used NOTE The threshold voltage of alarm input is below 5 V Recommended RELAY Alarm Out connection Mechanical alarm output device can be used as above NC NO is a relay output which sinks 2A 125VAC and 1A 30VDC ...

Page 20: ...ayback Mode Button 5 Clip Copy LED 14 Menu Cameo Button 6 Camera Buttons 15 Enter Pause Button 7 Zoom PTZ Button 16 Arrow Buttons 8 Panic Button 17 USB Connector 9 Display SPOT Button Display Modes Press the desired camera number button to view the desired camera image and press the Display button repeatedly to toggle between different display formats 4x4 3x3 2x2 and PIP Recording Once you have in...

Page 21: ...or longer enters the cameo mode The yellow outline surrounding the video indicates the active cameo and pressing the arrow buttons moves the active cameo Pressing the desired camera button in the active cameo edits the cameo and displays the video of selected camera Pressing the Enter Pause button exits the Active Cameo mode Selecting Exit Group Edit in the cameo menu displayed when pressing the M...

Page 22: ...electronic products should be disposed of separately from the municipal waste stream via designated collection facilities appointed by the government or the local authorities This crossed out wheeled bin symbol on the product means the product is covered by the European Directive 2002 96 EC The correct disposal and separate collection of your old appliance will help prevent potential negative cons...

Page 23: ......

Page 24: ...llee 84 D 76187 Karlsruhe Tel 49 721 595 1 www buildingtechnologies siemens com 2010 Copyright by Siemens AG Data and design subject to change without notice Supply subject to availability Document no A6V10315395 Edition 06 05 2010 ...