Administration Manual – Terxon L
18
Event Description
CNFG CHANGE ###
Configuration of user ### changed
CNFG CHANGE ####
Configuration of user #### changed
CODE ##
Code of user ## entered
CODE ###
Code of user ### entered
CODE ####
Code of user #### entered
CODE LOCK # OFF
Code lock # off
CODE LOCK # ON
Code lock # on
CODE LOCKED ##
User number ## tried to enter user code while locked.
CODE LOCKED ###
User number ### tried to enter user code while locked.
CODE LOCKED ####
User number #### tried to enter user code while locked.
CODE TAMPER
Operating panel locked for 5 min due to invalid user code entry
COMMS FAILED
Integrated modem could not connect to emergency command centre
COMMS TEST CALL
Test call started
CONFIG CHANGE ##
User configuration ## changed
DATE CHANGED AT
System date changed on …
DATE CHANGED TO
System date changed to …
DEFAULT USER
User code 01 (administrator) to default
DEFAULT USER ##
Not used
DEFAULT USER ###
Not used
DEFAULT USER ####
Not used
DEFERRED SET:-
Delayed activation of partitions
DL DISCONNECT FL)
Downloader disconnected with an error
DL DISCONNECT OK
Downloader disconnected
DURESS CODE ##
Duress alarm user ##
DURESS CODE ###
Duress alarm user ###
DURESS CODE ####
Duress alarm user ####
ENG HW DEFAULTED
Factory reset of alarm centre
ENGINEER ARRIVES
Engineer has logged into the system.
ENGINEER DEPARTS
Engineer has logged out of the system.
ENTRY TIME-OUT:-
Entry timeout in partition expired
ENTRY ZONE ####
Entry timeout of zone #### started.
EXIT CANCELLED:-
Exit timeout for partition … cancelled.
EXIT STARTED:-
Exit timeout for partition … started.
EXT LINE FAULT
Not used
EXT LINE RESTORE
Not used
FACTORY RESTART
Factory settings loaded
FIRE ALARM ####
Fire alarm in zone ####
FIRE PARTITIONS:-
Fire alarm in partition
FIRE RESET:-
Fire alarm reset
FIRST KNOCK ####
First activation of zone number #### (zones with the double
confirmation attribute)
FROM REMOTE #,##
Not used
HI-SECURITY SET:
Activation of partitions with high security
KEYPAD PANIC ###
Panic alarm triggered on operating panel ### (keys 1 and 3 pressed)
KEYSWITCH ###
Keyswitch zone #### activated
LOCAL ON LINE
Local connection with downloader
LOCAL SERV CALL
Local connection with downloader
LOCAL SERV END
Not used
LOCKSET #### ON
Keyswitch zone #### activated
LOCKSET #### OFF
Keyswitch zone #### deactivated
LOCKSET PARTITION ON
Key for partition released
MAIN POWER ON
Mains power on in the alarm centre
MAINS POWER OFF
Mains power off in the alarm centre
MASK FLT S ####
Zone #### masked during activation
MASK FLT U ####
Zone #### masked during deactivation
MASK TMP S ####
Masking zone #### masked during activation
MASK TMP U ####
Masking zone #### masked during activation
MENU TIMEOUT ##
Menu abort for user ## and return to standby display
MENU TIMEOUT ###
Menu abort for user ### and return to standby display
MENU TIMEOUT ####
Menu abort for user #### and return to standby display
MODEM LOCKOUT
Modem locked (after 4 failed attempts)
NETWORK # FUSE
Fuse in bus # triggered
NODE TAMP OMIT
Wired auxiliary tamper omitted after expiry of confirmation period
NORM. REST. ####
Normal alarm restored
OCCUPANCY SET
System activation during operation
ON LINE TO #
Online to remote access point
ON-SITE RESTART
Restart in the installation
PA PARTITIONS:-
Panic alarm in partitions
PANEL LID TAMPER
Tamper in panel lid of alarm centre
PANEL STARTED
Alarm centre is operational
Summary of Contents for Terxon LX
Page 1: ...Perfect security for home and office Inv 11738099 Terxon LX ADMINISTRATION MANUAL ...
Page 2: ......
Page 26: ...Administration Manual Terxon L 24 6 2 User Data No Name Type Partitions 1 Administrator ...
Page 27: ...Administration Manual Terxon L 25 6 3 Zone Data No Location Door chime Partition ...
Page 28: ...Administration Manual Terxon L 26 6 4 Maintenance Date Name Work ...