������������ ���� ���������� ������������ 13
ABS lifting station Sanimat
4.10
Ch��k���� ���������� �f ��������
m
The safety hints in the previous sections must be observed!
When three phase units are being commissioned for the first time and also when used on a new site, the
direction of rotation must be carefully checked by a qualified person.
c
The direction of rotation should only be altered by a qualified person.
ATTENTION
The following characteristics of a submersible pump indicate a probable incorrect
direction of rotation.
Submersible pump runs unevenly and vibrates strongly.
Submersible pump does not achieve full output and the emptying times for the collection tank are too long.
The submersible pump makes unusual running noises.
4.11
������������ �f �h� �����������
4.11.1 ������������ �f �h� H���� M�mb���� P�m� (w��� m�������)
1086-00
Figure 17 Installation of hand membrane pump
ATTENTION
The discharge line (1) from the hand membrane pump must be installed
independently of the discharge line of the ABS submersible sewage pump, and
likewise must be provided with an anti-siphon loop located above the sewer
backwash level. The discharge lines must be brought to a location after the anti-
siphon loop.
Determine a fixing location for the hand membrane pump, which is easily accessible and fasten using plugs (3)
and screws (7).
Open the connection port (8) on the collection tank in accordance with Figure 5 using a saw.
Bring the pipe line (6) from the hand membrane pump to the collection tank and connect to the outlet port (8)
chosen with the aid of flexible junction piece (4) including clamps.
ATTENTION
The hand membrane pump should never be fastened to the collection tank.