26 Installation of the Wallbox eM4 Single
Proceed as follows:
1
Prepare the drilling template for insertion of the cables, if
necessary.
J
If directly inserting the power line from behind, cut the
grommet marked
C
on the drilling template.
J
If inserting the data and control cables, cut the grom-
mets marked
DATA
and
EXT. CONTROL
on the drilling
template.
C
NOTE
Recommended cable lengths for wiring in the wallbox
ABL recommends the following cable lengths to ensure problem-free connection in the wallbox:
x
Power line: at least 130 mm
x
Data cable: at least 170 mm
x
Control cable: at least 130 mm
ATTENTION
Length of data and control cable
Please note that the length of the data and control cables from the tapping point (router, switch, ripple control receiver, VDE-FNN
control box, etc.) has been tested to a maximum of 30 metres.
2
Using the spirit level, align the drilling template level and
plumb on the installation position.
3
With the pencil, mark the four fixing points.