EN - 8
BAL.0212.0 • 2018-07-16
4 Putting into operation
PP
4.2 Mounting the liner
4.2.1 Liner
To be used for steel wires.
1
Lay down the cable assembly
straight and unscrew nut
from central connector
.
2
Slide the liner
through the wire conduit
until a noticeable resistance is felt in the inlet
.
3
Determine excess length x and pull out the liner
again.
4
Shorten the liner
by the dimension x.
5
Debur the cutting point and sharpen the spiral beginning to an angle
of 40°.
6
Insert the liner cut to length
.
7
Screw down nut
and secure with multiple wrench
NOTICE
• New still unused liners or PA liners have to be shortened to the actual length of the cable
assembly.
1
Torch neck
2
Inlet nipple
3
Wire conduit
4
Central connector
5
Multiple wrench
6
Nut
7
Holding nipple
8
Liner
9
Cable assembly
Fig. 2
Liner
40°
1
9
2
4
8
5
6
7
4 – 5 mm
x
3
40°