EN - 32
BAL.0737.0 • 2019-11-15
13 Appendix
iROB Feed HA
13.5 Alarm codes
Alarm code
Alarm symbol
Alarm type
Possible remedial action
E01, E02, E03
Temperature alarm
Note duty cycle.
E07
Alarm for supply to wire feed motor
Internal error. Contact the Service
Department.
E08
Alarm motor blocked
Check wire feed system incl. liner and
wear parts for ease of operation.
E10
Alarm for power module
Internal error. Contact the Service
Department.
E11, E19
Alarm for system configuration
Incorrect firmware in individual
components. Contact the Service
Department.
E12
Communication alarm (WF-DSP)
Check cables.
(Intermediate cable assembly)
E13
Communication alarm (FP)
Check control panel cable
(incl. plug).
E14, E15, E18
Alarm program invalid
Reset power source. If errors persist,
contact the Service Department.
E16
Communication alarm (RI)
Check power supply to interface.
Internal error: Contact the Service
Department.
External error: Check voltage
(+24 V).
E17
Communication
alarm
(
µ
P-DSP)
Reset power source. If errors persist,
contact the Service Department.
E20
Alarm for memory error
Reset power source. If errors persist,
contact the Service Department.
E21, E32
Alarm for data loss
Reset power source. If errors persist,
contact the Service Department.
E22
Alarm for LCD display
Reset power source. If errors persist,
contact the Service Department.
E29
Alarm for inconsistent measurements
Inconsistent measurement results
Power source may be in test mode for
electric safety check. Contact the
Service Department.
E30
Communication alarm (HF)
Malfunction in communication
between components
Check cables.
E38
Alarm for undervoltage
Have mains voltage checked by a
technician (under full load).
E39, E40
Alarm for system’s power supply
Have mains voltage checked by a
technician (under full load).
Contact the Service Department.
E43
Alarm for empty coolant
Refill coolant.
Tab. 17
Alarm codes