EN - 4
BAL.0153 • 2018-08-24
3 Product Description
ALPHA FLUX
2.3 Emergency information
In the event of an emergency, immediately disconnect the following supplies:
• Electrical power supply
Further measures can be found in the operating instructions for the power source or the
documentation for other peripheral devices.
3 Product Description
3.1 Technical Data
CAUTION
Describes a potentially harmful situation. If not avoided, this may result in slight or minor
injuries.
NOTICE
Describes the risk of impairing work results or potential material damage to the equipment.
WARNING
Hazards caused by improper use
If improperly used, the device can present risks to persons, animals and material property.
• Use the device according to its designated use only.
• Do not convert or modify the device to enhance its performance without authorization.
• The device must only be used by qualified personnel (in Germany, see TRBS 1203).
Transport and storage
- 30 °C to + 55°C
Relative humidity
up to 90 % at 20 °C
Tab. 1
Ambient conditions during operation
Type of voltage
DC
DC polarity of the electrodes
Usually positive
Shielding gas (DIN EN ISO 14175)
without
Wire types
Self-shielding fluxed-core wire electrodes
Type of use
manual
Voltage rating
113 V peak value
Protection type of the machine-side connections
(EN 60 529)
IP3X
Tab. 2
General torch data (EN 60 974-7)