EN - 12
BAL.0153 • 2018-08-24
9 Maintenance and cleaning
ALPHA FLUX
9.1 Torch neck
1
Remove welding spatters from the contact tip, the insulator and the protective shield and
spray them with original
BINZEL
®
anti-spatter agent.
2
Check wear parts for visible damage and replace them, if required.
9.2 Coaxial cable
1
Check all screw joints for tight fit.
2
Replace wire guide liner when worn or soiled.
3
Replace defective, deformed or worn parts.
BINZEL
®
offers repair services at the factory.
9.3 Cleaning the wire guide
1
Lay out the welding torch in stretched position.
2
Unscrew retaining sleeve / clamping screw and pull out liner.
3
Clean liner and coaxial cable from both sides with compressed air.
4
Slide adjusted liner into coaxial cable and secure with retaining sleeve / clamping screw.
DANGER
Risk of burns
Burns caused by hot parts (torch, welded parts).
• Allow the torch to cool down completely
WARNING
Risk of injury
Serious injuries caused by parts swirling around.
• When cleaning the wire guide with compressed air, wear suitable protective clothing, in
particular safety goggles.